Show simple item record

dc.contributor.authorJuvonen, Riitta
dc.contributor.authorParviainen, Annika Jenni Johana 
dc.contributor.authorLoukola-Ruskeeniemi, Kirsti
dc.date.accessioned2024-10-29T07:20:23Z
dc.date.available2024-10-29T07:20:23Z
dc.date.issued2009
dc.identifier.citationJuvonen, R., Parviainen, A., & Loukola-Ruskeeniemi, K. (2009). Evaluation of a total reflection x-ray fluorescene spectrometer in the determination of arsenic and trace metals in environmental samples. Geochemistry: Exploration, Environment, Analysis, 9(2), 173-178. https://doi.org/10.1144/1467-7873/09-205es_ES
dc.identifier.urihttps://hdl.handle.net/10481/96419
dc.description.abstractSuitability of the PicoTAX total reflection X-ray fluorescence (TXRF) spectrometer was studied for determination of As and trace metals in the Haveri Au-Cu sulphide mine tailings leached with aqua regia and in water affected by acid mine drainage. Results for 12 water and 16 tailings samples were compared with accredited methods, inductively coupled plasma-atomic emission spectrometry (ICP-AES) and inductively coupled plasma-mass spectrometry (ICP-MS). Certified reference samples analysed were QC Metal LL from Eurofins A/S, and groundwater CRM 609 and lake sediment BCR-280R from the Institute for Reference Materials and Measurements (IRMM) of the European Commission. Approximate method detection limits (MDL) for water samples, based on reference sample analyses, are in the range of 20 μg l-1 for As, Cr, Pb and Zn and 5–10 μg l-1 for Co, Cu, Ni, V and Mn. MDLs for aqua regia leach, calculated using reagent blank values, were 20 (mg kg-1) for As, Co, Cr, Cu, Mn, Ni, V, and Zn. Random error of determination varied from 12 to 20 %. Inter-element interferences include: As and Pb on each other, and Fe on Cr and Co. Using the Mo anode of the X-ray tube excludes the determination of Cd, Mo, Nb, Tc and Zr. TXRF can be recommended merely as a preliminary technique for selecting samples.es_ES
dc.language.isoenges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTXRFes_ES
dc.subjecttotal reflection X-ray fluorescencees_ES
dc.subjectarsenic es_ES
dc.subjecttrace metalses_ES
dc.subjectmine tailingses_ES
dc.subjectsurface wateres_ES
dc.subjectacid mine drainagees_ES
dc.titleEvaluation of a total reflection x-ray fluorescene spectrometer in the determination of arsenic and trace metals in environmental sampleses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsembargoed accesses_ES
dc.identifier.doihttps://doi.org/10.1144/1467-7873/09-205