Afficher la notice abrégée

dc.contributor.authorFranco-López, Francisco
dc.contributor.authorDurkalec-Michalski, Krzysztof
dc.contributor.authorDíaz Morón, Jesús
dc.contributor.authorHigueras-Liébana, Enrique
dc.contributor.authorHernández-Belmonte, Alejandro
dc.contributor.authorCourel Ibáñez, Javier 
dc.date.accessioned2024-09-02T10:32:39Z
dc.date.available2024-09-02T10:32:39Z
dc.date.issued2024-06-25
dc.identifier.citationFranco, López, F. et. al. Sensors 2024, 24, 4131. [https://doi.org/10.3390/s24134131]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/93757
dc.description.abstractExercise is a front-line intervention to increase functional capacity and reduce pain and disability in people with low strength levels or disorders. However, there is a lack of validated field-based tests to check the initial status and, more importantly, to control the process and make tailored adjustments in load, intensity, and recovery. We aimed to determine the test–retest reliability of a submaximal, resistance-band test to evaluate the strength of the trunk stability muscles using a portable force sensor in middle-aged adults (48 ± 13 years) with medically diagnosed chronic low back pain and healthy peers (n = 35). Participants completed two submaximal progressive tests of two resistance-band exercises (unilateral row and Pallof press), consisting of 5 s maintained contraction, progressively increasing the load. The test stopped when deviation from the initial position by compensation movements occurred. Trunk muscle strength (CORE muscles) was monitored in real time using a portable force sensor (strain gauge). Results revealed that both tests were highly reliable (intra-class correlation [ICC] > 0.901) and presented low errors and coefficients of variation (CV) in both groups. In particular, people with low back pain had errors of 14–19 N (CV = 9–12%) in the unilateral row test and 13–19 N (CV = 8–12%) in the Pallof press. No discomfort or pain was reported during or after the tests. These two easy-to-use and technology-based tests result in a reliable and objective screening tool to evaluate the strength and trunk stability in middle-aged adults with chronic low back pain, considering an error of measurement < 20 N. This contribution may have an impact on improving the individualization and control of rehabilitation or physical training in people with lumbar injuries or disorders.es_ES
dc.description.sponsorshipResearch Transfer Office of the University of Murcia (R-1471/2019)es_ES
dc.description.sponsorshipExchange Programme for Scientists as part of bilateral cooperation (project No. BPN/BIL/2021/1/00108/U/00001) financed by The Polish National Agency for Academic Exchangees_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectmusculoskeletal paines_ES
dc.subjectphysical fitnesses_ES
dc.subjectspine es_ES
dc.titleUsing Resistance-Band Tests to Evaluate Trunk Muscle Strength in Chronic Low Back Pain: A Test–Retest Reliability Studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/s24134131
dc.type.hasVersionVoRes_ES


Fichier(s) constituant ce document

[PDF]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Atribución 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Atribución 4.0 Internacional