Mostrar el registro sencillo del ítem
The impact of human occupancy in thermal performance of a historic religious building in sub-humid temperate climate
dc.contributor.author | Vázquez-Torres, Claudia Eréndira | |
dc.contributor.author | Beizaee, Arash | |
dc.contributor.author | Bienvenido Huertas, José David | |
dc.date.accessioned | 2022-02-18T09:53:43Z | |
dc.date.available | 2022-02-18T09:53:43Z | |
dc.date.issued | 2022-03-15 | |
dc.identifier.citation | Claudia Eréndira Vázquez-Torres, A. Beizaee and D. Bienvenido-Huertas. The impact of human occupancy in thermal performance of a historic religious building in sub-humid temperate climate. Energy & Buildings 259 (2022) 111912 [https://doi.org/10.1016/j.enbuild.2022.111912] | es_ES |
dc.identifier.uri | http://hdl.handle.net/10481/72901 | |
dc.description.abstract | The level of human occupancy in historic religious buildings influences the internal heat gains and thus the thermal comfort of the users. The temperate climate represents a challenge due to variations in tem- perature and relative humidity throughout the year, which are by no means extreme. Knowledge regard- ing human occupancy in historic religious buildings in temperate climates increases the possibilities of controlling and staying within a given comfort range for the users benefit. The objective was to determine the impact of occupancy on the thermal performance of a historic religious building located in sub-humid temperate climate, to increase the knowledge and to generate opportunities to decrease the excessive use of active systems prevalent today. The objective was approached with a numerical method that included monitoring periods and dynamic simulation to determine a novel passive cooling system that would maintain a determined comfort tem- perature for the longest time in summer. By implementing a novel passive cooling system, the results showed an impact on the operative temperature according to occupancy level, which reduced the cooling degree-hour by 80% and 66% at the upper occupancy with 80% and 90% satisfaction levels, respectively. | es_ES |
dc.description.sponsorship | Universidad de Granada / CBUA | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Dynamic simulation | es_ES |
dc.subject | Thermal performance | es_ES |
dc.subject | Religious buildings | es_ES |
dc.subject | Occupancy impact | es_ES |
dc.subject | Passive cooling system | es_ES |
dc.title | The impact of human occupancy in thermal performance of a historic religious building in sub-humid temperate climate | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.identifier.doi | 10.1016/j.enbuild.2022.111912 | |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es_ES |