Mostrar el registro sencillo del ítem

dc.contributor.authorJerez Mayorga, Daniel Alejandro 
dc.contributor.authorHuerta Ojeda, Álvaro
dc.contributor.authorChirosa Ríos, Luis Javier 
dc.contributor.authorGuede Rojas, Francisco Alfonso
dc.contributor.authorGuzmán Guzmán, Iris Paola
dc.contributor.authorIntelangelo, Leonardo
dc.contributor.authorMiranda Fuentes, Claudia
dc.contributor.authorDelgado Floody, Pedro 
dc.date.accessioned2021-07-05T10:56:07Z
dc.date.available2021-07-05T10:56:07Z
dc.date.issued2021
dc.identifier.citationJerez-Mayorga, D.; Huerta-Ojeda, Á.; Chirosa-Ríos, L.J.; Guede-Rojas, F.; Guzmán-Guzmán, I.P.; Intelangelo, L.; Miranda-Fuentes, C.; Delgado-Floody, P. Test–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults. Int. J. Environ. Res. Public Health 2021, 18, 6829. https:// doi.org/10.3390/ijerph18136829es_ES
dc.identifier.urihttp://hdl.handle.net/10481/69515
dc.description.abstractBackground: The purpose of this study was to determine the reliability for the strength and movement velocity of the concentric phase from the five Sit-to-Stand (5STS), using three incremental loads measured by a functional electromechanical dynamometer (FEMD) in healthy young adults. Methods: The average and peak strength and velocity values of sixteen healthy adults (mean ± standard deviation (SD): age = 22.81 ± 2.13 years) were recorded at 5, 10 and 15 kg. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results: Reliability was high for the 10 kg (CV range: 3.70–4.18%, ICC range: 0.95–0.98) and 15 kg conditions (CV range: 1.64–3.02%, ICC: 0.99) at average and peak strength, and reliability was high for the 5 kg (CV range: 1.71–2.84%, ICC range: 0.96–0.99), 10 kg (CV range: 0.74–1.84%, ICC range: 0.99–1.00) and 15 kg conditions (CV range: 0.79–3.11%, ICC range: 0.99–1.00) at average and peak velocity. Conclusions: The findings of this study demonstrate that FEMD is a reliable instrument to measure the average and peak strength and velocity values during the five STS in healthy young adults.es_ES
dc.description.sponsorshipFEDER/Ministry of Science, Innovation and Universities—State Research Agency (Dossier number: RTI2018-099723-B-I00)es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectReproducibilityes_ES
dc.subjectIsokinetices_ES
dc.subjectMuscles es_ES
dc.titleTest–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adultses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.3390/ijerph18136829


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España