Mostrar el registro sencillo del ítem

dc.contributor.authorFernández Mateo, Fernando
dc.contributor.authorOrtiz Gómez, Inmaculada 
dc.contributor.authorOrtega Muñoz, Mariano 
dc.contributor.authorMarín-Sánchez, Antonio
dc.contributor.authorOrbe Payá, Ignacio De 
dc.contributor.authorHernández Mateo, Fernando 
dc.contributor.authorCapitán Vallvey, Luis Fermín 
dc.contributor.authorSantoyo González, Francisco 
dc.contributor.authorSalinas Castillo, Alfonso 
dc.date.accessioned2026-01-28T09:36:14Z
dc.date.available2026-01-28T09:36:14Z
dc.date.issued2020
dc.identifier.citationPublished version: Ortiz-Gomez, I., Ortega-Muñoz, M., Marín-Sánchez, A. et al. A vinyl sulfone clicked carbon dot-engineered microfluidic paper-based analytical device for fluorometric determination of biothiols. Microchim Acta 187, 421 (2020). https://doi.org/10.1007/s00604-020-04382-9es_ES
dc.identifier.urihttps://hdl.handle.net/10481/110401
dc.descriptionThis study was supported by projects from the Spanish MINECO (CTQ2017-86125 and CTQ2016-78754-C2-1-R). The project was also partially supported by the European Regional Development Funds (ERDF).es_ES
dc.description.abstractA microfluidic paper-based analytical device integrating carbon dot (CDs) is fabricated and used for a fluorometric off-on assay of biothiols. Vinyl sulfone (VS) click immobilization of carbon dots (CDs) on paper was accomplished by a one-pot simplified protocol that uses divinyl sulfone (DVS) as a homobifunctional reagent. This reagent mediated both the click oxa-Michael addition to the hydroxyl groups of cellulose and ulterior covalent grafting of the resulting VS paper to NH2-functionalized CDs by means of click aza-Michael addition. The resulting cellulose nanocomposite was used to engineer an inexpensive and robust microfluidic paper-based analytical device (μPAD) that is used for a reaction-based off-on fluorometric assay of biothiols (GSH, Cys, and Hcy). The intrinsic blue fluorescence of CDs (with excitation/emission maxima at 365/450 nm) is turned off via the heavy atom effect of an introduced iodo group. Fluorescence is turned on again due to the displacement of iodine by reaction with a biothiol. The increase in fluorescence is related to the concentration over a wide range (1 to 200 μM for GSH and 5–200 μM for Cys and Hcy, respectively), and the assay exhibits a low detection limit (0.3 μM for GSH and Cys and 0.4 μM for Hcy). The method allows for rapid screening and can also be used in combination with a digital camera readoutes_ES
dc.description.sponsorshipSpanish MINECO (CTQ2017-86125 and CTQ2016-78754-C2-1-R)es_ES
dc.description.sponsorshipEuropean Regional Development Funds (ERDF)es_ES
dc.language.isoenges_ES
dc.publisherSpringer Naturees_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMicrofluidic paper-based devicees_ES
dc.subjectOff-on assayes_ES
dc.subjectCarbon dotses_ES
dc.titleA vinyl sulfone clicked carbon dot-engineered microfluidic paper-based analytical device for fluorometric determination of biothiolses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1007/s00604-020-04382-9


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional