Validity and reliability of NOTCH® inertial sensors for measuring elbow joint angle during tennis forehand at different sampling frequencies
Metadatos
Afficher la notice complèteAuteur
Ruíz Malagón, Emilio José; Castro Infantes, Santiago; Ritacco Real, Maximiliano; Soto Hermoso, Víctor ManuelEditorial
Elsevier
Materia
IMU Motion capture 3D joint kinematics Racket sports Multi-sensor fusion
Date
2022-07-30Referencia bibliográfica
Emilio J. Ruiz-Malagón... [et al.]. Validity and reliability of NOTCH® inertial sensors for measuring elbow joint angle during tennis forehand at different sampling frequencies, Measurement, Volume 201, 2022, 111666, ISSN 0263-2241, [https://doi.org/10.1016/j.measurement.2022.111666]
Résumé
Portable and low-cost motion capture systems are gaining importance for biomechanical analysis. The aim was to
determine the concurrent validity and reliability of the NOTCH® inertial sensors to measure the elbow angle
during tennis forehand at different sampling frequencies (100, 250 and 500 Hz), using an optical capture system
with sub-millimetre accuracy as a reference. 15 competitive players performed forehands wearing NOTCH and
an upper body marker-set and the signals from both systems were adjusted and synchronized. The error
magnitude was tolerable (5-10◦) for all joint-axis and sampling frequencies, increasing significantly at 100 Hz for
the flexion–extension and pronation-supination angles (p = 0.002 and 0.023; Cohen d > 0.8). Concordance
correlation coefficient was very large (0.7–0.9) in all cases. The within-subject error variation between the
test–retest did not show significant differences (p > 0.05). NOTCH® is a valid, reliable and portable alternative
to measure elbow angles during tennis forehand.