Mostrar el registro sencillo del ítem

dc.contributor.authorRus Carlborg, Guillermo 
dc.contributor.authorAbdelkader, Esraa M.
dc.contributor.authorNassar, Khaled
dc.contributor.authorMelchor, Juan
dc.date.accessioned2021-05-07T10:59:56Z
dc.date.available2021-05-07T10:59:56Z
dc.date.issued2021
dc.identifier.citationAbdelkader, E.M.; Rus, G.; Nassar, K.; Melchor, J. Braiding Thermoplastic and Glass Fibers in Composite Dental Post Improves Their Mechanical Compatibility, In Vitro Experiment. Materials 2021, 14, 2294. https://doi.org/10.3390/ ma14092294es_ES
dc.identifier.urihttp://hdl.handle.net/10481/68390
dc.description.abstractMechanical compatibility with the human dentin is a considerable issue when fabricating dental fiber posts. To this purpose, this study introduces a new method of fabricating compatible dental posts using braiding techniques of thermoplastic fibers (matrix) with glass fibers (reinforcement). Fifty fiber-reinforced composite (FRC) posts of thermoplastic yarns polypropylene (PP) braided with continuous filaments glass fibers (GFs) for reinforcement, varying in fiber volume fraction (FVF), and core types are fabricated and tested. Posts are performed using a braiding machine, and braids are placed in an aluminum mold. The filled mold is playced inside an oven at the melting temperature of the polypropylene to produce the final post’s shape. An ultrasonic test is conducted to measure the shear modulus and Young’s modulus of FRC post specimens by measuring the velocities of both the P-wave and S-wave. In order to ensure the accuracy of the measurements, each sample is measured three times, and then the means and standard deviations of each sample are calculated before analyzing the test results using the means of two steps, namely, clustering and comparing the P and R² values of each cluster, which revealed that FVF, fiber mass, and core type of the specimen had a significant effect on the resulted Young’s and shear modulus. The results indicate that the proposed method can fabricate competitive dental posts with regard to different fabricating variables. The samples show Young’s modulus ranges of from 10.08 GPa to 31.83 GPa. The following tested hypothesis is supported: the braiding technique of thermoplastic fibers with glass fibers will improve the mechanical compatibility of the resulting posts (ex vivo).es_ES
dc.description.sponsorshipMinistry of Science and Innovation, Spain grant numbers DPI2017-83859-R, PID2019-106947RA-C22es_ES
dc.description.sponsorship(FEDER) EQC2018-004508-Pes_ES
dc.description.sponsorshipMinistry of Health, Spain, grant number PI16/00339es_ES
dc.description.sponsorshipJunta de Andalucía IE2017-5537 and PI-0107-201es_ES
dc.description.sponsorshipErasmus+es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectDental materials es_ES
dc.subjectRoot canal postses_ES
dc.subjectFiber-reinforced composites (FRCs)es_ES
dc.subjectYoung’s moduluses_ES
dc.subjectShear moduluses_ES
dc.subjectFiber volume fraction (FVF)es_ES
dc.subjectEndodontics es_ES
dc.titleBraiding Thermoplastic and Glass Fibers in Composite Dental Post Improves Their Mechanical Compatibility, In Vitro Experimentes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.3390/ ma14092294


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España