Photoacoustic molecular imaging for in vivo liver iron quantitation

[PDF] Maccarinelli_Photoacoustic.pdf (2.342Mo)
Identificadores
URI: http://hdl.handle.net/10481/47249
DOI: 10.1117/1.JBO.21.5.056008
ISSN: 1083-3668
ISSN: 1560-2281
Exportar
RISRefworksMendeleyBibtex
Estadísticas
Statistiques d'usage de visualisation
Metadatos
Afficher la notice complète
Auteur
Maccarinelli, Federica; Carmona Rodríguez-Acosta, Fernando; Regoni, Maria; Arosio, Paolo
Editorial
Society of Photo-optical Instrumentation Engineers (SPIE)
Materia
Photoacoustic
 
Iron
 
Ferritin
 
Multispetral optoacoustic tomography
 
Date
2016
Referencia bibliográfica
Maccarinelli, F.; et al. Photoacoustic molecular imaging for in vivo liver iron quantitation. Journal of Biomedical Optics 21(5): 056008 (2016). [http://hdl.handle.net/10481/47249]
Patrocinador
The work was partially supported by PRIN10-11 grant to P.A. F.M. was partially supported by a fellowship by Consorzio Interuniversitario Biotecnologie.
Résumé
A recent study showed that ferritin is a suitable endogenous contrast agent for photoacoustic molecular imaging in cultured mammalian cells. We have therefore tested whether this imaging technique can be used for in vivo quantification of iron in mouse livers. To verify this hypothesis, we used multispectral optoacoustic tomography (MSOT) to image albino CD1 mice before and after experimental iron loading. Postmortem assays showed that the iron treatment caused a 15-fold increase in liver iron and a 40-fold increase in liver ferritin levels, while in vivo longitudinal analysis using MSOT revealed just a 1.6-fold increase in the ferritin/iron photoacoustic signal in the same animals. We conclude that MSOT can monitor changes in ferritin/iron levels in vivo, but its sensitivity is much lower than that of ex vivo iron assays.
Colecciones
  • DQI - Artículos

Mon compte

Ouvrir une sessionS'inscrire

Parcourir

Tout DIGIBUGCommunautés et CollectionsPar date de publicationAuteursTitresSujetsFinanciaciónPerfil de autor UGRCette collectionPar date de publicationAuteursTitresSujetsFinanciación

Statistiques

Statistiques d'usage de visualisation

Servicios

Pasos para autoarchivoAyudaLicencias Creative CommonsSHERPA/RoMEODulcinea Biblioteca UniversitariaNos puedes encontrar a través deCondiciones legales

Contactez-nous | Faire parvenir un commentaire