TY - GEN AU - Marchamalo Sacristán, Miguel AU - Lamas Fernández, Francisco J. PY - 2023 UR - https://hdl.handle.net/10481/83822 AB - The Benínar Dam, located in Southeastern Spain, is an earth-fill dam that has experienced filtration issues since its construction in 1985. Despite the installation of various monitoring systems, the data collected are sparse and inadequate for the... LA - eng PB - MDPI KW - InSAR KW - Embankment dams KW - FEM KW - Auscultation KW - Subsidence TI - MT-InSAR and Dam Modeling for the Comprehensive Monitoring of an Earth-Fill Dam: The Case of the Benínar Dam (Almería, Spain) DO - 10.3390/rs15112802 ER -