Mostrar el registro sencillo del ítem
Exploring the optical behavior and relative translucency parameter of CAD-CAM resin-based composites, polymer-infiltrated ceramic network, and feldspar porcelain
dc.contributor.author | Arruda Mascaro, Bruno | |
dc.contributor.author | Tejada Casado, María de la Nativida | |
dc.contributor.author | García Fonseca, Renata | |
dc.contributor.author | dos Santos Nunes Reis, José Maurício | |
dc.contributor.author | Pérez Gómez, María Del Mar | |
dc.date.accessioned | 2024-11-27T12:00:09Z | |
dc.date.available | 2024-11-27T12:00:09Z | |
dc.date.issued | 2024-11-13 | |
dc.identifier.citation | Arruda Mascaro, B. et. al. Dental Materials 40 (2024) 1954–1961. [https://doi.org/10.1016/j.dental.2024.09.007] | es_ES |
dc.identifier.uri | https://hdl.handle.net/10481/97461 | |
dc.description.abstract | Objectives: To evaluate and compare the optical properties and relative translucency parameter of CAD-CAM restorative materials. Methods: Four CAD-CAM materials were evaluated: Lava Ultimate (LU), Grandio Blocs (GB), VITA Enamic (VE), and VITA Mark II (VM). Disk-shaped samples in shade A2-HT were prepared (n = 10) and polished to 1.00 ± 0.01 mm of thickness. Scattering (S), absorption (K), albedo (a) coefficient, transmittance (T%), light reflectivity (RI), infinite optical thickness (X∞), and radiative transfer coefficients (μa, and μ′S) were calculated using Kubelka-Munk method and Thennadil’s semi-empirical approach. Root Mean Square Error (RMSE) and Goodness of Fit (GFC) were used as performance optical behavior. Translucency differences were evaluated using the relative translucency parameter (RTP00) and 50:50 % translucency perceptibility and acceptability thresholds (TPT00 and TAT00). Results: The spectral distribution of S, K, T%, RI, and X∞ was wavelength-dependent. GFC and RMSE values indicated good spectral behavior matches and good comparative spectral values for RI in LU-GB, LU-VE, and GBVE, and for K in VE-VM. VM displayed the highest scattering values across the wavelengths, while VE and VM showed lower absorption at shorter wavelengths. LU and GB had the highest transmittance. The X∞ values indicated that all 1.0 mm thick materials could be influenced by the background. No good spectral match and no good comparative spectral values were found between CAD-CAM materials and anterior bovine maxillary specimens. VM had the lowest RTP00 values with perceptible and unacceptable differences compared to CADCAM materials evaluated. Significance: Understanding the optical behavior of different CAD-CAM materials was essential for guiding clinicians in material selection and optimizing their clinical performance. The findings confirm that the different compositions and microstructure impact the optical properties and translucency of CAD-CAM restorative materials. | es_ES |
dc.description.sponsorship | Sao Paulo State Research Foundation (FAPESP) [grant numbers #2022/12430–9, #2022/12431–5, and 2023/15441–4] | es_ES |
dc.description.sponsorship | Grant PID2022.142151OB.I00 funded by MICIU/AEI/ 10.13039/501100011033 and by FEDER, UE | es_ES |
dc.description.sponsorship | Grant C-EXP-276- UGR23 funded by Consejería de Universidad, Investigación e Innovación and by FEDER Andalusia Program 2021–2027 | es_ES |
dc.description.sponsorship | Universidad de Granada/CBUA | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | CAD-CAM materials | es_ES |
dc.subject | Kubelka-Munk theory | es_ES |
dc.subject | Optical properties | es_ES |
dc.title | Exploring the optical behavior and relative translucency parameter of CAD-CAM resin-based composites, polymer-infiltrated ceramic network, and feldspar porcelain | es_ES |
dc.type | journal article | es_ES |
dc.rights.accessRights | open access | es_ES |
dc.identifier.doi | 10.1016/j.dental.2024.09.007 | |
dc.type.hasVersion | VoR | es_ES |