Afficher la notice abrégée

dc.contributor.authorMula Pérez, Francisco Javier 
dc.contributor.authorManzano Sánchez, David
dc.contributor.authorChirosa Ríos, Luis Javier 
dc.contributor.authorChirosa Ríos, Ignacio Jesús 
dc.contributor.authorRodríguez Perea, Ángela 
dc.date.accessioned2024-09-12T10:40:31Z
dc.date.available2024-09-12T10:40:31Z
dc.date.issued2024-09-03
dc.identifier.citationMula-Pérez, F.; Manzano-Sánchez, D.; Chirosa-Ríos, L.J.; Chirosa-Ríos, I.J.; Rodríguez- Perea, Á. A Specific Test of Starting Blocks: Intrasession and Intersession Reliability of Isometric Strength Using a Functional Electromechanical Dynamometer. Appl. Sci. 2024, 14, 7778. https://doi.org/10.3390/app14177778es_ES
dc.identifier.urihttps://hdl.handle.net/10481/94390
dc.description.abstractAims: To determine the intrasession and intersession reliability of the isometric force at three different starting block positions, to compare the intrasession and intersession reliability of the peak and average isometric force of three different starting block positions, and to compare the intrasession and intersession reliability of three different starting block positions. Methods: Eighteen male college students participated in this study. A repeated measures design was used to evaluate the intrasession and intersession reliability of isometric force in three different starting block positions. Results: Very high and extremely high reliability of the average and peak isometric force of the three positions of the starting blocks were obtained, with ICC ranging from 0.63 to 0.91 and a CV close to 10%. Peak force was able to determine the outcomes of the bilateral position with higher reliability than the mean force, and the dominant was the most reliable position for assessing the starting blocks. Conclusion: The functional electromechanical dynamometer can be used with a high level of reliability to assess the force exerted in the starting blocks.es_ES
dc.description.sponsorshipFinanced by Consejo Superior de Deportes 09/UBP/24 (Universidad de Granada Red de Dinamometría Funcional Deportiva)es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectAthletic performancees_ES
dc.subjectReproducibility of resultses_ES
dc.subjectAthleteses_ES
dc.titleA Specific Test of Starting Blocks: Intrasession and Intersession Reliability of Isometric Strength Using a Functional Electromechanical Dynamometeres_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/app14177778
dc.type.hasVersionVoRes_ES


Fichier(s) constituant ce document

[PDF]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Atribución 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Atribución 4.0 Internacional