Mostrar el registro sencillo del ítem

dc.contributor.authorAndrades Ramírez, Oscar Andrés
dc.contributor.authorUlloa Díaz, David
dc.contributor.authorAlfaro Castillo, Bryan
dc.contributor.authorArroyo Jofré, Patricio
dc.contributor.authorCastillo Paredes, Antonio
dc.contributor.authorCHIROSA RÍOS, LUIS JAVIER 
dc.date.accessioned2024-09-05T11:18:03Z
dc.date.available2024-09-05T11:18:03Z
dc.date.issued2024-06-26
dc.identifier.citationAndrades Ramírez, O. et. al. Sports 2024, 12, 175. [https://doi.org/10.3390/sports12070175]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/94019
dc.description.abstractThe purpose of the study was to analyze the test–retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test–retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65–5.02%; ICC = 0.99–0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71–9.61%; ICC = 0.98–0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963–0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectmuscular strengthes_ES
dc.subjectreliabilityes_ES
dc.subjectdynamometeres_ES
dc.titleTest–Retest Reliability of an Isometric and Isometric/ Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometryes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/sports12070175
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional