| dc.description.abstract | One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor.
An international standard for light ion beam systems sets two recommended limits for out-of-field dose based
on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of
the maximum dose at distances 15 cm to 50 cm from the field edge. At distances > 50 cm from the field
edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works
focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam
Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we
characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been
assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has
been analyzed for the equivalent dose computation. It is concluded that our design for a future acceleratorbased
source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both
equivalent and effective dose outside the field. | es_ES |
| dc.description.sponsorship | Spanish Ministerio de Ciencia e Innovación (Proyectos de I+D+i:
PID2020-117969RB-I00) | es_ES |
| dc.description.sponsorship | Junta de Andalucía, Spain (Andalusian
Regional Government, P20-00665 and Programa Operativo FEDER
Andalucia 2014–2020 under contracts A-FQM-371-UGR18, B-FQM-
156-UGR20) | es_ES |
| dc.description.sponsorship | Spanish La Caixa Foundation | es_ES |
| dc.description.sponsorship | University Chair ‘‘Neutrons for Medicine’’: Fundación
ACS, Capitán Antonio, La Kuadrilla de Iznalloz, Sonriendo se Puede
Ganar and Costaleros Contra el Cáncer, Spai | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | Elsevier | es_ES |
| dc.rights | Atribución 4.0 Internacional | * |
| dc.rights | Atribución 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.subject | BNCT | es_ES |
| dc.subject | Neutrons | es_ES |
| dc.subject | Out-of-field | es_ES |
| dc.title | Study of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapy | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | 10.1016/j.apradiso.2024.111458 | |