Mostrar el registro sencillo del ítem

dc.contributor.authorVerdera, Antònia
dc.contributor.authorTorres Sánchez, Pablo 
dc.contributor.authorPraena Rodríguez, Antonio Javier 
dc.contributor.authorPorras Sánchez, José Ignacio 
dc.date.accessioned2024-09-03T07:57:38Z
dc.date.available2024-09-03T07:57:38Z
dc.date.issued2024-07-27
dc.identifier.citationVerdera, A. et. al. 212 (2024) 111458. [https://doi.org/10.1016/j.apradiso.2024.111458]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/93803
dc.description.abstractOne important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances > 50 cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future acceleratorbased source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.es_ES
dc.description.sponsorshipSpanish Ministerio de Ciencia e Innovación (Proyectos de I+D+i: PID2020-117969RB-I00)es_ES
dc.description.sponsorshipJunta de Andalucía, Spain (Andalusian Regional Government, P20-00665 and Programa Operativo FEDER Andalucia 2014–2020 under contracts A-FQM-371-UGR18, B-FQM- 156-UGR20)es_ES
dc.description.sponsorshipSpanish La Caixa Foundationes_ES
dc.description.sponsorshipUniversity Chair ‘‘Neutrons for Medicine’’: Fundación ACS, Capitán Antonio, La Kuadrilla de Iznalloz, Sonriendo se Puede Ganar and Costaleros Contra el Cáncer, Spaies_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAtribución 4.0 Internacional*
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectBNCTes_ES
dc.subjectNeutrons es_ES
dc.subjectOut-of-fieldes_ES
dc.titleStudy of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.apradiso.2024.111458
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional