Afficher la notice abrégée

dc.contributor.authorSaez Berlanga, Ángel
dc.contributor.authorBabiloni Lopez, Carlos
dc.contributor.authorFerri Caruana, Ana
dc.contributor.authorJiménez Martínez, Pablo
dc.contributor.authorGarcía Ramos, Amador 
dc.contributor.authorFlandez, Jorge
dc.contributor.authorGene Morales, Javier
dc.contributor.authorColado, Juan C.
dc.date.accessioned2024-05-16T10:30:48Z
dc.date.available2024-05-16T10:30:48Z
dc.date.issued2024-03-06
dc.identifier.citationSaez-Berlanga A, Babiloni-Lopez C, Ferri-Caruana A, Jiménez-Martínez P, García-Ramos A, Flandez J, Gene-Morales J, Colado JC. 2024. A new sports garment with elastomeric technology optimizes physiological, mechanical, and psychological acute responses to pushing upper-limb resistance exercises. PeerJ 12:e17008 DOI 10.7717/peerj.17008es_ES
dc.identifier.urihttps://hdl.handle.net/10481/91870
dc.description.abstractThis study aimed to compare the mechanical (lifting velocity and maximum number of repetitions), physiological (muscular activation, lactate, heart rate, and blood pressure), and psychological (rating of perceived exertion) responses to upper-body pushing exercises performed wearing a sports elastomeric garment or a placebo garment. Nineteen physically active young adults randomly completed two training sessions that differed only in the sports garment used (elastomeric technology or placebo). In each session, subjects performed one set of seated shoulder presses and another set of push-ups until muscular failure. The dependent variables were measured immediately after finishing the set of each exercise. Compared to the placebo garment, the elastomeric garment allowed participants to obtain greater muscular activation in the pectoralis major (push-ups: p = 0.04, d = 0.49; seated shoulder press: p < 0.01, d = 0.64), triceps brachialis (push-ups, p < 0.01, d = 0.77; seated shoulder press: p < 0.01, d = 0.65), and anterior deltoid (push-ups: p < 0.01, d = 0.72; seated shoulder press: p < 0.01, d = 0.83) muscles. Similarly, participants performed more repetitions (push-ups: p < 0.01; d = 0.94; seated shoulder press: p = 0.03, d = 0.23), with higher movement velocity (all p ≤ 0.04, all d ≥ 0.47), and lower perceived exertion in the first repetition (push-ups: p < 0.01, d = 0.61; seated shoulder press: p = 0.05; d = 0.76) wearing the elastomeric garment compared to placebo. There were no between-garment differences in most cardiovascular variables (all p ≥ 0.10). Higher diastolic blood pressure was only found after the seated shoulder press wearing the elastomeric garment compared to the placebo (p = 0.04; d = 0.49). Finally, significantly lower blood lactate levels were achieved in the push-ups performed wearing the elastomeric garment (p < 0.01; d = 0.91), but no significant differences were observed in the seated shoulder press (p = 0.08). Overall, the findings of this study suggest that elastomeric technology integrated into a sports garment provides an ergogenic effect on mechanical, physiological, and psychological variables during the execution of pushing upper-limb resistance exercises.es_ES
dc.language.isoenges_ES
dc.publisherPeerJes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectVariable resistance traininges_ES
dc.subjectStrength traininges_ES
dc.subjectElastic bandses_ES
dc.titleA new sports garment with elastomeric technology optimizes physiological, mechanical, and psychological acute responses to pushing upper-limb resistance exerciseses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.7717/peerj.17008
dc.type.hasVersionVoRes_ES


Fichier(s) constituant ce document

[PDF]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Atribución 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Atribución 4.0 Internacional