Mostrar el registro sencillo del ítem
Clinical Reliability of IgG, IgA, and IgM Antibodies in Detecting Epstein-Barr Virus at Different Stages of Infection With a Commercial Nonrecombinant Polyantigenic ELISA
dc.contributor.author | Gutiérrez Fernández, José | |
dc.contributor.author | Vergara, M.J. | |
dc.contributor.author | Piédrola Angulo, Gonzalo | |
dc.contributor.author | Maroto Vela, María del Carmen | |
dc.date.accessioned | 2024-04-09T11:10:09Z | |
dc.date.available | 2024-04-09T11:10:09Z | |
dc.date.issued | 1999-02-11 | |
dc.identifier.citation | Gutiérrez et al. Clinical reliability of IgG, IgA, and IgM antibodies in detecting Epstein-Barr virus at different stages of infection with a commercial nonrecombinant polyantigenic ELISA. J Clin Lab Anal. 1999;13(2):65-8. https://doi.org/10.1002/(SICI)1098-2825(1999)13:2<65::AID-JCLA4>3.0.CO;2-O | es_ES |
dc.identifier.uri | https://hdl.handle.net/10481/90550 | |
dc.description.abstract | We studied the diagnostic reliability of a modification of the Enzygnost EBV test (Behringwerke, Germany) for the detection of IgG, IgA, and IgM antibodies (Abs) in the diagnosis of Epstein-Barr virus (EBV) disease. One hundred and twenty-three serum samples were studied: 14 asymptomatic subjects without EBV infection, 48 patients with primary infection, 46 subjects with past EBV infection (11 patients with other acute infections), 8 patients without EBV infection but with other viral infection, and 7 patients with probable acute clonal stimulation of B lymphocytes caused by different microorganisms. Enzygnost EBV is based on an ELISA test with a pool of viral antigens. In our series the reliability of IgM for the diagnosis of recent primary EBV infection was: sensitivity 100%, specificity 95%, positive predictive value 90.5%, and negative predictive value 100%. The IgG detection with Enzygnost was: sensitivity 98%, specificity 100%, positive predictive value 100%, and negative predictive value 91.7%. Only two subjects had positive IgA. The Enzygnost test is an efficient method for the diagnosis of EBV infection although a few IgM false positives can occur. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Wiley | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Epstein-Barr virus | es_ES |
dc.subject | ELISA | es_ES |
dc.subject | Antibodies | es_ES |
dc.title | Clinical Reliability of IgG, IgA, and IgM Antibodies in Detecting Epstein-Barr Virus at Different Stages of Infection With a Commercial Nonrecombinant Polyantigenic ELISA | es_ES |
dc.type | journal article | es_ES |
dc.rights.accessRights | open access | es_ES |
dc.identifier.doi | 10.1002/(SICI)1098-2825(1999)13:2<65::AID-JCLA4>3.0.CO;2-O | |
dc.type.hasVersion | VoR | es_ES |