Mostrar el registro sencillo del ítem

dc.contributor.authorBienvenido Huertas, José David 
dc.contributor.authorRodríguez-Álvaro, Roberto
dc.contributor.authorMoyano, Juan J.
dc.contributor.authorRico, Fernando
dc.contributor.authorMarín, David
dc.date.accessioned2024-02-06T12:37:29Z
dc.date.available2024-02-06T12:37:29Z
dc.date.issued2018-02-03
dc.identifier.urihttps://hdl.handle.net/10481/88448
dc.description.abstractThe thermal transmittance of building envelopes determines to a large extent the energy demand of buildings. Thus, there is a keen interest in having methods which can precisely evaluate thermal transmittance. From a scientific point of view, this study analyses the viability of the application of the thermometric method (THM), one of the most used methods in Spain. For this purpose, the test method has been improved by determining the adequate test conditions, the selection and installation of equipment, data acquisition and post-processing, and the estimation of uncertainty. We analyse eight case studies in a Mediterranean climate (Csa) to determine the potentials and limitations of the method. The results show that the values obtained through THM are valid under winter environmental conditions with relative uncertainties between 6% and 13%, while difficulties to perform the test in optimal conditions, and therefore to obtain valid results in warmer seasons, are detected. In this regard, the case studies which obtained a greater number of observations by performing the filtrate conditions were able to obtain representative results. Furthermore, there are significant differences depending on the kind of equipment and probes used during the experimental campaign. Finally, in warm climate regions a data filtrate can be considered for observations of a temperature difference higher than 5 °C, obtaining valid results for the case studies, although the rise in the thermal gradient can guarantee a greater stability of data.es_ES
dc.language.isoenges_ES
dc.publisherEnergieses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectthermal transmittance (U-value)es_ES
dc.subjectthermometric method (THM)es_ES
dc.subjectfaçades es_ES
dc.subjectinternal convective coefficientes_ES
dc.subjectin situ measurementes_ES
dc.titleDetermining the U-Value of Façades Using the Thermometric Method: Potentials and Limitationses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/en11020360
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional