Mobile phone platform as portable chemical analyzer

[PDF] Artículo principal (1017.Kb)
Identificadores
URI: https://hdl.handle.net/10481/87251
DOI: 10.1016/j.snb.2011.04.045
Exportar
RISRefworksMendeleyBibtex
Estadísticas
View Usage Statistics
Metadata
Show full item record
Author
García Ríos, Antonio; Erenas Rodríguez, Miguel María; Marinetto, Eugenio D.; Abad, Carlos; Orbe Payá, Ignacio De; Palma López, Alberto José; Capitán Vallvey, Luis Fermín
Editorial
Elsevier
Date
2011
Referencia bibliográfica
Sensors and Actuators B 156 (2011) 350–359
Sponsorship
We acknowledge financial support from the Ministerio de Ciencia e Innovación, Dirección General de Investigación y Gestión del Plan Nacional de I+D+i (Spain) (Projects CTQ2009-14428- C02-01 and CTQ2009-14428-C02-02); and the Junta de Andalucía (Proyecto de Excelencia P08-FQM-3535). These projects were partially supported by European Regional Development Funds (ERDF)
Abstract
In this work, a mobile phone platform for portable chemical analysis is presented. This platform is based on the use of the built-in camera for capturing the image of a single-use colorimetric chemical sensor, while a custom-developed software application processes this image for obtaining its characteristic H (hue) value, which is related to analyte concentration. This software application is optimized for mobile phone usage, thus preserving battery life and targeting reduced computation time through a customized image processing scheme including a modified monodimensional edge detection algorithm. Meanwhile, the influence of physical and chemical factors has been characterized, with results showing that the presented platform provides accurate results even when variations on distance from phone to sensor, image focusing, or image centering are induced. In the same way, factors such as indicator concentration and membrane thickness have been shown to have negligible effects on the obtained H values. The calibration and testing procedures have shown that the presented platform is able to provide a detection limit of3.1×10−5 M in a range of3.1×10−5–0.1Mwith a relative standard deviation for inter-membrane reproducibility lower than 1.6% for potassium concentration determination in solution.
Collections
  • ECsens - Artículos

My Account

LoginRegister

Browse

All of DIGIBUGCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectFinanciaciónAuthor profilesThis CollectionBy Issue DateAuthorsTitlesSubjectFinanciación

Statistics

View Usage Statistics

Servicios

Pasos para autoarchivoAyudaLicencias Creative CommonsSHERPA/RoMEODulcinea Biblioteca UniversitariaNos puedes encontrar a través deCondiciones legales

Contact Us | Send Feedback