Mostrar el registro sencillo del ítem
Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome
dc.contributor.author | Cavaggion, Claudia | |
dc.contributor.author | Navarro Ledesma, Santiago | |
dc.date.accessioned | 2023-09-01T11:43:52Z | |
dc.date.available | 2023-09-01T11:43:52Z | |
dc.date.issued | 2023-02-10 | |
dc.identifier.citation | Cavaggion, C., Navarro-Ledesma, S., Juul-Kristensen, B. et al. Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome. Sci Rep 13, 2383 (2023). [https://doi.org/10.1038/s41598-023-29601-0] | es_ES |
dc.identifier.uri | https://hdl.handle.net/10481/84196 | |
dc.description.abstract | This study investigated the intra-rater reliability of a novice ultrasound (US) examiner and the interrater reliability of two examiners (novice, expert) in the measures of coracohumeral distance at rest (CHD) and at 60° of elevation without (CHD60) or with weights (CHD60w), tendon thickness of the long head of the biceps (LHB) and subscapularis (SCP). Twenty-one patients with subacromial pain syndrome (SAPS) and 20 asymptomatic participants were included. Intra and inter-rater reliability were tested with intraclass-correlation-coefficient (ICC), differences between raters were analyzed with Bland–Altman plots. Intra-rater reliability for CHD, CHD60 and CHD60w was excellent (ICC = 0.97– 0.98) in asymptomatic participants, and good-to-excellent (0.88–0.93) in SAPS, while intra-rater reliability for LHB and SCP was good-to-excellent in asymptomatic participants (0.88–0.97) and in SAPS (0.90–0.92). Inter-rater reliability for CHD, CHD60 and CHD60w was moderate-to-good (0.70– 0.90) in asymptomatic participants and good (0.85–0.87) in SAPS, in contrast inter-rater reliability for LHB and SCP was poor in asymptomatic participants (0.10–0.46) and poor-to-moderate (0.49–0.61) in SAPS. Bland–Altman plots revealed systematic and/or proportional bias for tendons’ thickness. A novice showed good-to-excellent intra-rater reliability in all US measures, whereas in comparison to an expert a novice can measure reliably CHD, CHD60 and CHD60w, but not LHB and SCP, where more training is recommended. | es_ES |
dc.description.sponsorship | University of Antwerp (grant number: 37063) | es_ES |
dc.description.sponsorship | Research Foundation Flanders—FWO (grant number: 1158121N) | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Springer Nature | es_ES |
dc.rights | Atribución 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.title | Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome | es_ES |
dc.type | journal article | es_ES |
dc.rights.accessRights | open access | es_ES |
dc.identifier.doi | 10.1038/s41598-023-29601-0 | |
dc.type.hasVersion | VoR | es_ES |