Mostrar el registro sencillo del ítem

dc.contributor.authorCavaggion, Claudia
dc.contributor.authorNavarro Ledesma, Santiago 
dc.date.accessioned2023-09-01T11:43:52Z
dc.date.available2023-09-01T11:43:52Z
dc.date.issued2023-02-10
dc.identifier.citationCavaggion, C., Navarro-Ledesma, S., Juul-Kristensen, B. et al. Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome. Sci Rep 13, 2383 (2023). [https://doi.org/10.1038/s41598-023-29601-0]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/84196
dc.description.abstractThis study investigated the intra-rater reliability of a novice ultrasound (US) examiner and the interrater reliability of two examiners (novice, expert) in the measures of coracohumeral distance at rest (CHD) and at 60° of elevation without (CHD60) or with weights (CHD60w), tendon thickness of the long head of the biceps (LHB) and subscapularis (SCP). Twenty-one patients with subacromial pain syndrome (SAPS) and 20 asymptomatic participants were included. Intra and inter-rater reliability were tested with intraclass-correlation-coefficient (ICC), differences between raters were analyzed with Bland–Altman plots. Intra-rater reliability for CHD, CHD60 and CHD60w was excellent (ICC = 0.97– 0.98) in asymptomatic participants, and good-to-excellent (0.88–0.93) in SAPS, while intra-rater reliability for LHB and SCP was good-to-excellent in asymptomatic participants (0.88–0.97) and in SAPS (0.90–0.92). Inter-rater reliability for CHD, CHD60 and CHD60w was moderate-to-good (0.70– 0.90) in asymptomatic participants and good (0.85–0.87) in SAPS, in contrast inter-rater reliability for LHB and SCP was poor in asymptomatic participants (0.10–0.46) and poor-to-moderate (0.49–0.61) in SAPS. Bland–Altman plots revealed systematic and/or proportional bias for tendons’ thickness. A novice showed good-to-excellent intra-rater reliability in all US measures, whereas in comparison to an expert a novice can measure reliably CHD, CHD60 and CHD60w, but not LHB and SCP, where more training is recommended.es_ES
dc.description.sponsorshipUniversity of Antwerp (grant number: 37063)es_ES
dc.description.sponsorshipResearch Foundation Flanders—FWO (grant number: 1158121N)es_ES
dc.language.isoenges_ES
dc.publisherSpringer Naturees_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleReliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndromees_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1038/s41598-023-29601-0
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional