Show simple item record

dc.contributor.authorCavaggion, Claudia
dc.contributor.authorNavarro Ledesma, Santiago 
dc.date.accessioned2023-09-01T11:43:52Z
dc.date.available2023-09-01T11:43:52Z
dc.date.issued2023-02-10
dc.identifier.citationCavaggion, C., Navarro-Ledesma, S., Juul-Kristensen, B. et al. Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome. Sci Rep 13, 2383 (2023). [https://doi.org/10.1038/s41598-023-29601-0]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/84196
dc.description.abstractThis study investigated the intra-rater reliability of a novice ultrasound (US) examiner and the interrater reliability of two examiners (novice, expert) in the measures of coracohumeral distance at rest (CHD) and at 60° of elevation without (CHD60) or with weights (CHD60w), tendon thickness of the long head of the biceps (LHB) and subscapularis (SCP). Twenty-one patients with subacromial pain syndrome (SAPS) and 20 asymptomatic participants were included. Intra and inter-rater reliability were tested with intraclass-correlation-coefficient (ICC), differences between raters were analyzed with Bland–Altman plots. Intra-rater reliability for CHD, CHD60 and CHD60w was excellent (ICC = 0.97– 0.98) in asymptomatic participants, and good-to-excellent (0.88–0.93) in SAPS, while intra-rater reliability for LHB and SCP was good-to-excellent in asymptomatic participants (0.88–0.97) and in SAPS (0.90–0.92). Inter-rater reliability for CHD, CHD60 and CHD60w was moderate-to-good (0.70– 0.90) in asymptomatic participants and good (0.85–0.87) in SAPS, in contrast inter-rater reliability for LHB and SCP was poor in asymptomatic participants (0.10–0.46) and poor-to-moderate (0.49–0.61) in SAPS. Bland–Altman plots revealed systematic and/or proportional bias for tendons’ thickness. A novice showed good-to-excellent intra-rater reliability in all US measures, whereas in comparison to an expert a novice can measure reliably CHD, CHD60 and CHD60w, but not LHB and SCP, where more training is recommended.es_ES
dc.description.sponsorshipUniversity of Antwerp (grant number: 37063)es_ES
dc.description.sponsorshipResearch Foundation Flanders—FWO (grant number: 1158121N)es_ES
dc.language.isoenges_ES
dc.publisherSpringer Naturees_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleReliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndromees_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1038/s41598-023-29601-0
dc.type.hasVersionVoRes_ES


Files in this item

[PDF]

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
Except where otherwise noted, this item's license is described as Atribución 4.0 Internacional