Afficher la notice abrégée

dc.contributor.authorRuiz Malagón, Emilio J.
dc.contributor.authorGarcía Pinillos, Felipe 
dc.contributor.authorMolina Molina, Alejandro
dc.contributor.authorSoto-Hermoso, Víctor M.
dc.contributor.authorRuiz-Alias, Santiago
dc.date.accessioned2023-05-15T07:52:47Z
dc.date.available2023-05-15T07:52:47Z
dc.date.issued2023-02-27
dc.identifier.citationRuiz-Malagón, E.J.; García-Pinillos, F.; Molina-Molina, A.; Soto-Hermoso, V.M.; Ruiz-Alias, S.A. RunScribe Sacral Gait Lab™ Validation for Measuring Pelvic Kinematics during Human Locomotion at Different Speeds. Sensors 2023, 23, 2604. [https://doi.org/10.3390/s23052604]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/81531
dc.description.abstractOptoelectronic motion capture systems are considered the gold standard for measuring walking and running kinematics parameters. However, these systems prerequisites are not feasible for practitioners as they entail a laboratory environment and time to process and calculate the data. Therefore, this study aims to evaluate the validity of the three-sensor RunScribe Sacral Gait Lab™ inertial measurement unit (IMU) in measuring pelvic kinematics in terms of vertical oscillation, tilt, obliquity, rotational range of motion, and the maximum angular rates during walking and running on a treadmill. Pelvic kinematic parameters were measured simultaneously using an eight-camera motion analysis system (Qualisys Medical AB, GÖTEBORG, Sweden) and the three-sensor RunScribe Sacral Gait Lab™ (Scribe Lab. Inc. San Francisco, CA, USA) in a sample of 16 healthy young adults. An acceptable level of agreement was considered if the following criteria were met: low bias and SEE (<0.2 times the between-subject differences SD), almost perfect (r > 0.90), and good reliability (ICC > 0.81). The results obtained reveal that the three-sensor RunScribe Sacral Gait Lab™ IMU did not reach the validity criteria established for any of the variables and velocities tested. The results obtained therefore show significant differences between the systems for the pelvic kinematic parameters measured during both walking and runninges_ES
dc.description.sponsorshipThe State Research Agency (SRA)es_ES
dc.description.sponsorshipThe European Regional Development Fund (ERDF) with the project EDUSPORT (REF: PID2020-115600RB-C21)es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectSacrumes_ES
dc.subjectVertical oscillationes_ES
dc.subjectTiltes_ES
dc.subjectObliquityes_ES
dc.subjectRotationes_ES
dc.titleRunScribe Sacral Gait Lab™ Validation for Measuring Pelvic Kinematics during Human Locomotion at Different Speedses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/s23052604
dc.type.hasVersionVoRes_ES


Fichier(s) constituant ce document

[PDF]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Atribución 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Atribución 4.0 Internacional