Mostrar el registro sencillo del ítem

dc.contributor.authorDel Cuerpo Rodríguez, Indya
dc.contributor.authorJerez Mayorga, Daniel Alejandro 
dc.contributor.authorDelgado Floody, Pedro 
dc.contributor.authorMorenas Aguilar, María Dolores
dc.contributor.authorChirosa Ríos, Luis Javier 
dc.date.accessioned2023-03-06T07:58:29Z
dc.date.available2023-03-06T07:58:29Z
dc.date.issued2023-01-11
dc.identifier.citationdel-Cuerpo, I... [et al.]. Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise. Int. J. Environ. Res. Public Health 2023, 20, 1289. [https://doi.org/10.3390/ijerph20021289]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/80406
dc.description.abstractBackground: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained. Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), andW(CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM. Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults.es_ES
dc.description.sponsorshipUniversity de La Frontera, Chilees_ES
dc.description.sponsorshipSpanish Government FPU19/02030es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectReproducibilityes_ES
dc.subjectMuscle strengthes_ES
dc.subjectDynamometeres_ES
dc.subjectIsokinetices_ES
dc.titleTest–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercisees_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/ijerph20021289
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional