Mostrar el registro sencillo del ítem

dc.contributor.authorRodríguez Torres, Diego José
dc.contributor.authorTorres Quintero, Lucía
dc.contributor.authorSegura Rodríguez, Diego
dc.contributor.authorGarrido Jiménez, José Manuel 
dc.contributor.authorEsteban Molina, María
dc.contributor.authorGomera Martínez, Francisco
dc.contributor.authorMoreno Escobar, Eduardo
dc.contributor.authorGarcía Orta, Rocío
dc.date.accessioned2022-12-12T09:13:55Z
dc.date.available2022-12-12T09:13:55Z
dc.date.issued2022-11-14
dc.identifier.citationTorres, D.J.R... [et al.]. Behavior of echocardiographic parameters of right ventricular function after tricuspid surgery. Sci Rep 12, 19447 (2022). [https://doi.org/10.1038/s41598-022-24048-1]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/78386
dc.description.abstractEvaluation of right ventricular (RV) function after tricuspid valve surgery is complex. The objective was to identify the most appropriate RV function parameters for this purpose. This prospective study included 70 patients undergoing cardiac and tricuspid valve (TV) surgery. RV size and function parameters were determined at 3 months and 1-year post-surgery. Categorical variables were analyzed with the McNemar test and numerical variables with the Student’s t-test for related samples or, when non-normally distributed, the Wilcoxon test. Spearman’s rho was used to determine correlations between variables at 3 months and 1 year. RV diameters were reduced at 3 months postsurgery and were then unchanged at 1 year. Tricuspid annular plane systolic excursion (TAPSE) and S′ wave values were worse at 3 months and then improved at 1 year (t-score-2.35, p 0.023; t-score-2.68; p 0.010). There was no significant reduction in free wall longitudinal strain (LS) or shortening fraction (SF) at 3 months (t-score 1.421 and − 1.251; p 0.218 and 0.172), and they were only slightly below presurgical values at 1 year. No relationship was found between RV function parameters and mortality or major complications. During the first few months after TV surgery, LS may be a more appropriate parameter to evaluate global ventricular function in comparison to TAPSE. At 1 year, good correlations are observed between TAPSE, S′ wave, and LS values.es_ES
dc.language.isoenges_ES
dc.publisherNaturees_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleBehavior of echocardiographic parameters of right ventricular function after tricuspid surgeryes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1038/s41598-022-24048-1
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional