Mostrar el registro sencillo del ítem

dc.contributor.authorTejada Casado, María de la Nativida 
dc.contributor.authorGhinea, Razvan Ionut 
dc.contributor.authorMartínez Domingo, Miguel Ángel 
dc.contributor.authorPérez Gómez, María Del Mar 
dc.contributor.authorCardona Pérez, Juan De La Cruz 
dc.contributor.authorRuiz López, Javier 
dc.contributor.authorHerrera Maldonado, Luis Javier 
dc.date.accessioned2022-12-05T12:07:47Z
dc.date.available2022-12-05T12:07:47Z
dc.date.issued2022-11-09
dc.identifier.citationTejada-Casado, M... [et al.]. Validation of a Hyperspectral Imaging System for Color Measurement of In-Vivo Dental Structures. Micromachines 2022, 13, 1929. [https://doi.org/10.3390/mi13111929]es_ES
dc.identifier.urihttps://hdl.handle.net/10481/78306
dc.description.abstractA full comprehension of colorimetric relationships within and between teeth is key for aesthetic success of a dental restoration. In this sense, hyperspectral imaging can provide point-wise reliable measurements of the tooth surface, which can serve for this purpose. The aim of this study was to use a hyperspectral imaging system for the colorimetric characterization of 4 in-vivo maxillary anterior teeth and to cross-check the results with similar studies carried out with other measuring systems in order to validate the proposed capturing protocol. Hyperspectral reflectance images (Specim IQ), of the upper central (UCI) and lateral incisors (ULI), were captured on 30 participants. CIE-L*a*b* values were calculated for the incisal (I), middle (M) and cervical (C) third of each target tooth. Delta E-ab* and Delta E-00 total color differences were computed between different tooth areas and adjacent teeth, and evaluated according to the perceptibility (PT) and acceptability (AT) thresholds for dentistry. Non-perceptible color differences were found between UCIs and ULIs. Mean color differences between UCI and ULI exceeded AT (Delta E-ab* = 7.39-7.42; Delta E-00 = 5.71-5.74) in all cases. Large chromatic variations between I, M and C areas of the same tooth were registered (Delta E-ab* = 5.01-6.07 and Delta E-00 = 4.07-5.03; Delta E-ab* = 5.80-8.16 and Delta E-00 = 4.37-5.15; and Delta E-ab* = 5.42-5.92 and Delta E-00 = 3.87-4.16 between C and M, C and I and M and I, respectively). The use of a hyperspectral camera has proven to be a reliable and effective method for color evaluation of in-vivo natural teeth.es_ES
dc.description.sponsorshipMCIN/AEI/ERDF "Una manera de hacer Europa" PGC2018-101904-A-I00 PID2021128317OB-I00es_ES
dc.description.sponsorshipJunta de Andalucia RDI P20-00200es_ES
dc.description.sponsorshipOTRI 4744es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectHyperspectral imaginges_ES
dc.subjectColor es_ES
dc.subjectDentistry es_ES
dc.titleValidation of a Hyperspectral Imaging System for Color Measurement of In-Vivo Dental Structureses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/mi13111929
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional