dc.description.abstractBackground: Standardized validation indices (i.e., accuracy, bias, and precision) provide a comprehensive comparison of step counting wearable technologies. Purpose: To expand a previously published child/youth catalog of validity indices to include adults (21–40, 41–60 and 61–85 years of age) assessed across a range of treadmill speeds (slow [0.8–3.2 km/h], normal [4.0–6.4 km/h], fast [7.2–8.0 km/h]) and device wear locations (ankle, thigh, waist, and wrist). Methods: Two hundred fifty-eight adults (52.5 ± 18.7 years, 49.6% female) participated in this laboratory-based study and performed a series of 5-min treadmill bouts while wearing multiple devices; 21 devices in total were evaluated over the course of this multi-year cross-sectional study (2015–2019). The criterion measure was directly observed steps. Computed validity indices included accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV). Results: Over the range of normal speeds, 15 devices (Actical, waist-worn ActiGraph GT9X, activPAL, Apple Watch Series 1, Fitbit Ionic, Fitbit One, Fitbit Zip, Garmin vivoactive 3, Garmin vivofit 3, waist-worn GENEActiv, NL-1000, PiezoRx, Samsung Gear Fit2, Samsung Gear Fit2 Pro, and StepWatch) performed at < 5% MAPE. The wrist-worn Acti‑ Graph GT9X displayed the worst accuracy across normal speeds (MAPE = 52%). On average, accuracy was compromised across slow walking speeds for all wearable technologies (MAPE = 40%) while all performed best across normal speeds (MAPE = 7%). When analyzing the data by wear locations, the ankle and thigh demonstrated the best accuracy (both MAPE = 1%), followed by the waist (3%) and the wrist (15%) across normal speeds. There were significant effects of speed, wear location, and age group on accuracy and bias (both p < 0.001) and precision (p ≤ 0.045). Conclusions: Standardized validation indices cataloged by speed, wear location, and age group across the adult lifespan facilitate selecting, evaluating, or comparing performance of step counting wearable technologies. Speed, wear location, and age displayed a significant effect on accuracy, bias, and precision. Overall, reduced performance was associated with very slow walking speeds (0.8 to 3.2 km/h). Ankle- and thigh-located devices logged the highest accuracy, while those located at the wrist reported the worst accuracy.es_ES
dc.description.sponsorshipUnited States Department of Health & Human Services National Institutes of Health (NIH) - USA NIH National Institute on Aging (NIA) 5R01AG049024es_ES
dc.language.isoenges_ES
dc.publisherBMCes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectAccelerometeres_ES
dc.subjectAccuracyes_ES
dc.subjectBiases_ES
dc.subjectMeasurementes_ES
dc.subjectPedometeres_ES
dc.subjectPhysical activityes_ES
dc.titleA catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE‑adults studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1186/s12966-022-01350-9
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional