dc.contributor.authorJaén Carrillo, Diego
dc.contributor.authorRuiz Alías, Santiago Alejo 
dc.contributor.authorChicano Gutiérrez, José M.
dc.contributor.authorRuíz Malagón, Emilio José
dc.contributor.authorGarcía Pinillos, Felipe 
dc.date.accessioned2022-06-02T10:48:32Z
dc.date.available2022-06-02T10:48:32Z
dc.date.issued2022-04-21
dc.identifier.citationJaén-Carrillo, D... [et al.]. Test-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameters. Sensors 2022, 22, 3201. [https://doi.org/10.3390/s22093201]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/75200
dc.description.abstractThe use of markerless motion capture systems is becoming more popular for walking and running analysis given their user-friendliness and their time efficiency but in some cases their validity is uncertain. Here, the test-retest reliability of the MotionMetrix software combined with the use of Kinect sensors is tested with 24 healthy volunteers for walking (at 5 km center dot h(-1)) and running (at 10 and 15 km center dot h(-1)) gait analysis in two different trials. All the parameters given by the MotionMetrix software for both walking and running gait analysis are tested in terms of reliability. No significant differences (p > 0.05) were found for walking gait parameters between both trials except for the phases of loading response and double support, and the spatiotemporal parameters of step length and step frequency. Additionally, all the parameters exhibit acceptable reliability (CV < 10%) but step width (CV > 10%). When analyzing running gait, although the parameters here tested exhibited different reliability values at 10 km center dot h(-1), the system provided reliable measurements for most of the kinematic and kinetic parameters (CV < 10%) when running at 15 km center dot h(-1). Overall, the results obtained show that, although some variables must be interpreted with caution, the Kinect + MotionMetrix system may be useful for walking and running gait analysis. Nevertheless, the validity still needs to be determined against a gold standard system to fully trust this technology and software combination.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectAnalysis es_ES
dc.subjectBiomechanics es_ES
dc.subjectGaites_ES
dc.subjectMarkerlesses_ES
dc.subjectTesting es_ES
dc.titleTest-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameterses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/s22093201
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España