dc.description.abstractThe aim of this study was to evaluate the effectiveness of smear layer removal after the use of different irrigation methods (passive ultrasonic irrigation (PUI), continuous ultrasonic irrigation (CUI), apical negative pressure irrigation and conventional irrigation) using scanning electron microscopy (SEM) as an analytical tool. A total of 100 single-canal teeth were decoronated and randomly divided into five groups (n = 20) according to the irrigation method used: conventional irrigation with front outlet syringe, conventional irrigation with lateral outlet syringe, apical negative pressure irrigation (EndoVac), PUI with Irrisafe and CUI with ProUltra PiezoFlow ultrasonic irrigation needle. Root canal preparation was performed with the ProTaper Gold system up to the F4 instrument, and 5.25% NaOCl was used as an irrigant. After chemical-mechanical preparation, the roots were split longitudinally, and the coronal, middle and apical thirds were examined. SEM digital photomicrographs were taken at x1000 magnification to evaluate the amount of smear layer in each root canal third; CUI significantly removed more smear layer than any other irrigant activation protocol (p < 0.05); CUI was more effective in removing the smear layer than the other irrigation protocols. However, none of the irrigation protocols were able to produce root canals completely free from smear layer.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectEndoVaces_ES
dc.subjectIrrigant activationes_ES
dc.subjectIrrisafees_ES
dc.subjectPassive ultrasonic irrigationes_ES
dc.subjectProUltra PiezoFlowes_ES
dc.subjectScanning electron microscopy es_ES
dc.subjectSmear layeres_ES
dc.titleEffectiveness of Different Irrigant Activation Systems on Smear Layer Removal: A Scanning Electron Microscopic Studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/jcm11041003
dc.type.hasVersionVoRes_ES


Fichier(s) constituant ce document

[PDF]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Atribución 3.0 España
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Atribución 3.0 España