Mostrar el registro sencillo del ítem

dc.contributor.authorAlcántara Alcántara, Juan Manuel 
dc.contributor.authorJurado Fasoli, Lucas 
dc.contributor.authorDote Montero, Manuel 
dc.contributor.authorMerchán Ramírez, Elisa 
dc.contributor.authorRuiz Ruiz, Jonatan 
dc.contributor.authorSánchez Delgado, Guillermo
dc.date.accessioned2022-04-04T07:24:00Z
dc.date.available2022-04-04T07:24:00Z
dc.date.issued2022-02-04
dc.identifier.citationJ.M.A. Alcantara... [et al.]. Validity of four commercially available metabolic carts for assessing resting metabolic rate and respiratory exchange ratio in non-ventilated humans, Clinical Nutrition, Volume 41, Issue 3, 2022, Pages 746-754, ISSN 0261-5614, [https://doi.org/10.1016/j.clnu.2022.01.031]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/74059
dc.descriptionSupported by the Spanish Ministry of Economy and Competitiveness via Retos de la Sociedad grant DEP2016-79512-R (to JRR), and European Regional Development Fund (ERDF); Spanish Ministry of Education grant (FPU15/04059 to JMAA; FPU19/01609 to LJF; and FPU18/03357 to MD-M); the University of Granada Plan Propio de Investigacion 2016-Excellence actions: Unit of Excellence on Exercise and Health (to JRR) -Plan Propio de Investigacion 2018 Programa Contratos-Puente and Programa Perfeccionamiento de Doctores (to GS-D); Junta de Andalucia, Consejeria de Conocimiento, Investigacion y Universidades grant SOMM17/6107/UGR (to JRR) via the ERDF; and the Fundacion Alfonso Martin Escudero (to GS-D); Funding for open access charge: Universidad de Granada/CBUA.es_ES
dc.description.abstractBackground & aims: The validity of most commercially available metabolic cart is mostly unknown. Thus, we aimed to determine the accuracy, precision, within-subject reproducibility, and concordance of RMR and RER measured by four commercially available metabolic carts [Cosmed Q-NRG, Vyaire Vyntus CPX, Maastricht Instruments Omnical, and Medgraphics Ultima CardiO2]. Further, we studied whether a previously proposed simulation-based post-calorimetric calibration of cart readouts [individual calibration control evaluation (ICcE)] modify the RMR and RER reproducibility and concordance. Methods: Three experiments simulating different RMR and RER by controlled pure gas (N-2 and CO2) infusions were conducted on 5 non-consecutive days. Moreover, 30-min methanol burns were performed on 3 non-consecutive days. Lastly, the RMR and RER of 29 young non-ventilated adults (11 women; 25 +/- 4 years-old; BMI: 24.1 +/- 3.2 kg/m(2)) were assessed twice using each instrument, 24 hours apart, under standardized conditions. Results: The Omnical presented the lowest measurement error for RER (Omnical = 1.7 +/- 0.9%; Vyntus = 4.5 +/- 2.0%; Q-NRG = 6.6 +/- 1.9%; Ultima = 6.8 +/- 6.5%) and EE (Omnical = 1.5 +/- 0.5%; Q-NRG = 2.5 +/- 1.3%; Ultima = 10.7 +/- 11.0%; Vyntus = 13.8 +/- 5.0%) in all in vitro experiments (controlled pure gas infusions and methanol burns). In humans, the 4 metabolic carts provided discordant RMR and RER estimations (all P < 0.001). No differences were detected in RMR within-subject reproducibility (P = 0.058; Q-NRG inter-day coefficient of variance = 3.6 +/- 2.5%; Omnical = 4.8 +/- 3.5%; Vyntus = 5.0 +/- 5.6%; Ultima = 5.7 +/- 4.6%), although the Ultima CardiO2 provided larger RER inter-day differences (4.6 +/- 3.5%) than the others carts (P = 0.001; Omnical = 1.9 +/- 1.7%; Vyntus = 2.1 +/- 1.3%; Q-NRG = 2.4 +/- 2.1%). The ICcE procedure did not modify the RMR or RER concordance and did not reduce the inter-day differences in any of the carts. Conclusions: The 4 metabolic carts provided discordant measurements of RMR and RER. Overall, the Omnical provides more accurate and precise estimations of RMR and RER than the Q-NRG, Vyntus and Ultima CardiO(2), and might be considered the best for assessing RMR and RER in non-ventilated humans. Finally, our results do not support the use of an ICcE procedure.es_ES
dc.description.sponsorshipSpanish Ministry of Economy and Competitiveness via Retos de la Sociedad grant DEP2016-79512-Res_ES
dc.description.sponsorshipEuropean Commission Spanish Government FPU15/04059 FPU19/01609 FPU18/03357es_ES
dc.description.sponsorshipUniversity of Granada Plan Propio de Investigacion 2016-Excellence actions: Unit of Excellence on Exercise and Healthes_ES
dc.description.sponsorshipPlan Propio de Investigacion 2018 Programa Contratos-Puente and Programa Perfeccionamiento de Doctoreses_ES
dc.description.sponsorshipJunta de Andalucia, Consejeria de Conocimiento, Investigacion y Universidades via the ERDF SOMM17/6107/UGRes_ES
dc.description.sponsorshipFundacion Alfonso Martin Escuderoes_ES
dc.description.sponsorshipUniversidad de Granada/CBUAes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectIndirect calorimetryes_ES
dc.subjectReliabilityes_ES
dc.subjectBasal metabolic ratees_ES
dc.titleValidity of four commercially available metabolic carts for assessing resting metabolic rate and respiratory exchange ratio in nonventilated humanses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.1016/j.clnu.2022.01.031
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España