Mostrar el registro sencillo del ítem

dc.contributor.authorGarcía Maceira, Tania
dc.contributor.authorGarcía Rubiño, María Eugenia 
dc.date.accessioned2022-01-27T12:08:27Z
dc.date.available2022-01-27T12:08:27Z
dc.date.issued2021-12-20
dc.identifier.citationGarcía-Maceira, T... [et al.]. Covalent Immobilization of Antibodies through Tetrazine-TCO Reaction to Improve Sensitivity of ELISA Technique. Biosensors 2021, 11, 524. [https://doi.org/10.3390/bios11120524]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/72522
dc.descriptionThis research was funded by Compra Publica Precomercial, Reference 2012/000069, Ministerio de Economia y Competitividad, Espana. ONCOVER project: Volatile compound detection system for early cancer diagnosis.es_ES
dc.description.abstractEnzyme-linked immunosorbent assay (ELISA) is routinely used to detect biomolecules related to several diseases facilitating diagnosis and monitoring of these, as well as the possibility of decreasing their mortality rate. Several methods have been carried out to improve the ELISA sensitivity through antibodies immobilization on the microtiter plates. Here, we have developed a strategy of antibodies immobilization to improve the ELISA sensitivity increasing the antibody density surface through the tetrazine (Tz)-trans-cyclooctene (TCO) reaction. For this, we prepared surfaces with tetrazine groups while the captured antibody was conjugated with TCO. The tetrazine surfaces were prepared in two different ways: (1) from aminated plates and (2) from Tz-BSA-coated plates. The surfaces were evaluated using two sandwich ELISA models, one of them using the low-affinity antibody anti-c-myc as a capture antibody to detect the c-myc-GST-IL8h recombinant protein, and the other one to detect the carcinoembryonic human protein (CEA). The sensitivity increased in both surfaces treated with tetrazine in comparison with the standard unmodified surface. The c-myc-GST-IL8h detection was around 10-fold more sensible on both tetrazine surfaces, while CEA ELISA detection increased 12-fold on surfaces coated with Tz-BSA. In conclusion, we show that it is possible to improve the ELISA sensitivity using this immobilization system, where capture antibodies bond covalently to surfaces.es_ES
dc.description.sponsorshipCompra Publica Precomercial, Ministerio de Economia y Competitividad, Espana 2012/000069es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectELISAes_ES
dc.subjectAntibodies immobilizationes_ES
dc.subjectTetrazinees_ES
dc.subjectTCOes_ES
dc.subjectCEAes_ES
dc.titleCovalent Immobilization of Antibodies through Tetrazine-TCO Reaction to Improve Sensitivity of ELISA Techniquees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.3390/bios11120524
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España