Mostrar el registro sencillo del ítem

dc.contributor.authorAparicio Muriana, María del Mar 
dc.contributor.authorCarmona Molero, Rocío 
dc.contributor.authorLara Vargas, Francisco Jesús 
dc.contributor.authorGarcía Campaña, Ana María 
dc.contributor.authorOlmo Iruela, María Monsalud Del 
dc.date.accessioned2021-10-21T10:17:13Z
dc.date.available2021-10-21T10:17:13Z
dc.date.issued2021-10-05
dc.identifier.citationAparicio-Muriana, M. M., Carmona-Molero, R., Lara, F. J., García-Campaña, A. M., & del Olmo-Iruela, M. (2021). Multiclass cyanotoxin analysis in reservoir waters: Tandem solid-phase extraction followed by zwitterionic hydrophilic interaction liquid chromatography-mass spectrometry. Talanta, 122929.es_ES
dc.identifier.urihttp://hdl.handle.net/10481/71025
dc.description.abstractThe presence of cyanobacteria and cyanotoxins in all water bodies, including ocean water and fresh water sources, represents a risk for human health as eutrophication and climate change are enhancing their level of proliferation. For risk assessment and studies on occurrence, the development of reliable and sensitive analytical approaches able to cover a wide range of cyanotoxins is essential. This work describes the development of an HILIC-MS/MS multiclass method for the simultaneous analysis of eight cyanotoxins in reservoir water samples belonging to three different classes according to their chemical structure: cyclic peptides (microcystin-LR, microcystin-RR and nodularin), alkaloids (cylindrospermopsin, anatoxin-a) and three non-protein amino acids isomers such as β-methylamino-L-alanine, 2,4-diaminobutyric acid and N-(2-aminoethyl)glycine). A SeQuant ZIC-HILIC column was employed to achieve the chromatographic separation in less than 12 min. Previously, a novel sample treatment based on a tandem solid-phase extraction (SPE) system using mixed cation exchange (MCX) and Strata-X cartridges was investigated with the aim of extracting and preconcentrating this chemically diverse group of cyanotoxins. The Strata-X cartridge, which was configured first in the line of sample flow, retained the low polar compounds and the MCX cartridge, which was at the bottom of the dual system, retained mainly the non-protein amino acids. The optimization procedure highlighted the importance of sample ion content for the recoveries of some analytes such as the isomers β-Nmethylamino-L-alanine and 2-4-diaminobutyric acid. Method validation was carried out in terms of linearity, limit of detection (LOD) and quantification (LOQ), recoveries, matrix effect and precision in terms of repeatability and intermediate precision. This work represents the first analytical method for the simultaneous analysis of these multiclass cyanotoxins in reservoir water samples, achieving LOQs in the very low range of 7·10-3 – 0.1 µg·L-1. Despite high recoveries obtained at the LOQ concentration levels (101.0-70.9%), relative standard deviations lower than 17.5% were achieved.es_ES
dc.description.sponsorshipRTI2018-097043-B-I00 financed by MCIN/ AEI /10.13039/501100011033/ FEDER “Una manera de hacer Europa”es_ES
dc.description.sponsorshipSpanish Network of Excellence in Sample preparation (RED2018-102522-T)es_ES
dc.description.sponsorshipFPU17/03810es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectHydrophilic interaction liquid chromatographyes_ES
dc.subjectMass spectrometry es_ES
dc.subjectMulticlass cyanotoxinses_ES
dc.subjectReservoir wateres_ES
dc.subjectTandem solid-phase extractiones_ES
dc.titleMulticlass cyanotoxin analysis in reservoir waters: tandem solid-phase extraction followed by zwitterionic hydrophilic interaction liquid chromatography-mass spectrometryes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doihttps://doi.org/10.1016/j.talanta.2021.122929
dc.type.hasVersionSMURes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España