Mostrar el registro sencillo del ítem

dc.contributor.authorSánchez Sánchez, Antonio Jesús
dc.contributor.authorChirosa Ríos, Luis Javier 
dc.contributor.authorChirosa Ríos, Ignacio Jesús 
dc.contributor.authorGarcía Vega, Agustín José
dc.contributor.authorJerez Mayorga, Daniel Alejandro 
dc.date.accessioned2021-09-15T07:51:05Z
dc.date.available2021-09-15T07:51:05Z
dc.date.issued2021-07-14
dc.identifier.citationSánchez-Sánchez AJ... [et al.] 2021. Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players. PeerJ 9:e11743 DOI [10.7717/peerj.11743]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/70208
dc.descriptionThis study was supported by FEDER/Ministry of Science, Innovation and UniversitiesState Research Agency (Dossier number: RTI2018-099723-B-I00). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.es_ES
dc.description.abstractBackground: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players. Methods: Nineteen federated male soccer players (20.74 ± 4.04 years) performed the SEHE at three different isokinetic velocities (20–40–60 cm/s). These evaluations were conducted in four sessions, two for familiarization and two for registration. The average and maximum load (N) of the three isokinetic velocities was calculated from the values obtained from the FEMD (Dynasystem , Bangalore). Results: The main results of this research showed that the reliability was high for the average load in the condition of 40 cm/s, presenting the highest ICC value (0.94). For maximum load, reliability was high in the condition of 20 cm/s. The manifestation of the most reliable load was the maximum load (ICC = 0.91–0.87). Conclusions: FEMD (Dynasystem , Bangalore) is a reliable device to evaluate the eccentric strength of the hamstring muscles in soccer players.es_ES
dc.description.sponsorshipFEDER/Ministry of Science, Innovation and UniversitiesState Research Agency RTI2018-099723-B-I00es_ES
dc.language.isoenges_ES
dc.publisherPeerJes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectIsokinetices_ES
dc.subjectEccentrices_ES
dc.subjectLower extremityes_ES
dc.subjectDynamometeres_ES
dc.subjectHamstringes_ES
dc.subjectSoccer players es_ES
dc.titleTest-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer playerses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.7717/peerj.11743
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España