Mostrar el registro sencillo del ítem
Aplicación del valor de tono de color directo para el control cromático del proceso de recubrimiento de tabletas farmacéuticas
dc.contributor.author | Murillo Fernández, Mac Arturo | |
dc.contributor.author | Montero Zeledón, Ernesto | |
dc.contributor.author | Gutiérrez Fallas, Dionisio | |
dc.contributor.author | Melgosa Latorre, Manuel | |
dc.contributor.author | Pacheco Molina, Jorge Andrés | |
dc.date.accessioned | 2021-05-05T11:12:23Z | |
dc.date.available | 2021-05-05T11:12:23Z | |
dc.date.issued | 2021-03-26 | |
dc.identifier.citation | Murillo-Fernández, M. A., Montero-Zeledón, E., Gutiérrez-Fallas, D., Melgosa-Latorre, M., & Pacheco-Molina, J. (2021). Aplicación del valor de tono de color directo para el control cromático del proceso de recubrimiento de tabletas farmacéuticas. Revista Tecnología En Marcha, 34(2), Pág. 37–47. [https://doi.org/10.18845/tm.v34i2.5016] | es_ES |
dc.identifier.uri | http://hdl.handle.net/10481/68341 | |
dc.description | Los autores agradecen la colaboración al Ministerio de Ciencia e Innovación del Gobierno de España (PID2019-107816GB-I00 / AEI / 10.13039/501100011033) | es_ES |
dc.description.abstract | Se propone una aplicación novedosa de la fórmula SCTV (Spot Color Tone Value) proveniente de la industria de reproducción gráfica, para el control de la calidad del proceso de recubrimiento de tabletas farmacéuticas. Se analizan dos procedimientos: uno mediante la obtención de los espectros de reflectancia, de los cuales se pueden derivar los atributos cromáticos, y otro a partir de la obtención de las coordenadas de color de una imagen fotográfica calibrada. Nuestro objetivo es reducir la necesidad de intervención, extracción y destrucción de tabletas durante el control de calidad, además de facilitar el control y evaluación del proceso de forma remota, generando respuestas en tiempo real para la toma de decisiones. | es_ES |
dc.description.abstract | A novel application of the SCTV (Spot Color Tone Value) formula from the graphic reproduction industry is proposed for the quality control of the pharmaceutical tablet coating process. Two procedures are analyzed: one by obtaining reflectance spectra, from which the chromatic attributes can be derived, and the other from obtaining the color coordinates of a calibrated photographic image. Our goal is to reduce the intervention, extraction and destruction of tablets during quality control, as well as simplify the control and evaluation of the process remotely, generating real-time responses for taking decisions. | es_ES |
dc.description.sponsorship | Ministerio de Ciencia e Innovación del Gobierno de España PID2019-107816GB-I00 / AEI / 10.13039/501100011033 | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Instituto Tecnológico de Costa Rica | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Valor de Tono de Color Directo | es_ES |
dc.subject | Murray-Davies | es_ES |
dc.subject | Yule-Nielsen | es_ES |
dc.subject | CIEDE2000 | es_ES |
dc.subject | Poder de Dispersión | es_ES |
dc.subject | Kubelka Munk | es_ES |
dc.subject | Spot Color Tone Value | es_ES |
dc.subject | Scattering Capability | es_ES |
dc.title | Aplicación del valor de tono de color directo para el control cromático del proceso de recubrimiento de tabletas farmacéuticas | es_ES |
dc.title.alternative | Application of the spot color tone value at pharmaceutical tablet coating process control | es_ES |
dc.type | journal article | es_ES |
dc.rights.accessRights | open access | es_ES |
dc.identifier.doi | 10.18845/tm.v34i2.5016 | |
dc.type.hasVersion | VoR | es_ES |