Mostrar el registro sencillo del ítem

dc.contributor.authorMathanlal, Thasshwin
dc.contributor.authorMartín-Torres, Javier
dc.date.accessioned2021-01-28T07:55:54Z
dc.date.available2021-01-28T07:55:54Z
dc.date.issued2020
dc.identifier.citationMathanlal, T., Nazarious, M. I., Mantas-Nakhai, R., Zorzano, M. P., & Martin-Torres, J. (2020). ATMO-vent: An adapted breathing atmosphere for COVID-19 patients. HardwareX, 8, [https://doi.org/10.1016/j.ohx.2020.e00145]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/66084
dc.description.abstractThe ongoing worldwide pandemic of coronavirus disease 2019 (COVID-19), has been one of the most significant challenges to humankind in centuries. The extremely contagious nature of the SARS-CoV-2 virus has put forth an immense pressure on the health sector. In order to mitigate the stress on the healthcare systems especially to battle the crisis of mechanical ventilators, we have designed a modular, and robust DIY ventilator, ATMOVent (Atmospheric Mixture Optimization Ventilator) which can be fully mounted within two days by two operators. The ATMO-Vent has been designed using low-cost, robust, Commercial Off The Shelf (COTS) components, with many features comparable to a fullfledged ventilator. ATMO-Vent has been designed based on the United Kingdom Medicines & Healthcare products Regulatory Agency (UK-MHRA) guidelines for Rapidly Manufactured Ventilator System (RMVS), yet is scalable to the specific requirements of different countries. ATMO-Vent is capable of adjusting the Fraction of Inspiratory Oxygen (FiO2) levels, Tidal Volume (TV), frequency of breaths, Inspiratory/Expiratory ratio (I/E), Peak Inspiratory Pressure (PIP) and Positive End-Expiratory Pressure (PEEP). ATMO-Vent can operate in two modes – Continuous Mandatory Ventilation (CMV) using VolumeControlled Ventilation (VCV) and in Assisted Control (AC) mode with pressure triggered by the patient. ATMO-Vent has undergone rigorous testing and qualifies under Class B Electric and Magnetic Compatibility (EMC) requirements of EN 55,011 CISPR 11 standards.es_ES
dc.description.sponsorshipSpanish State Research Agency (AEI) Project No. MDM-2017-0737 Unidad de Excelencia ‘‘María de Maeztu”- Centro de Astrobiología (INTA-CSIC).es_ES
dc.language.isoenges_ES
dc.publisherELSEVIERes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectMechanic ventilationes_ES
dc.subjectAir-oxygen mixinges_ES
dc.subjectLow-costes_ES
dc.subjectRapid development timees_ES
dc.subjectCommercial off the shelfes_ES
dc.subjectCOVID-19
dc.titleATMO-vent: An adapted breathing atmosphere for COVID-19 patientses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.ohx.2020.e00145


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España