Mostrar el registro sencillo del ítem

dc.contributor.authorMolina-Molina, Alejandro
dc.contributor.authorRuiz-Malagón, Emilio
dc.contributor.authorCarrillo Pérez, Francisco 
dc.contributor.authorRoche Seruendo, Luis Enrique
dc.contributor.authorDamas Hermoso, Miguel 
dc.contributor.authorUbago Jiménez, José Luis 
dc.contributor.authorGarcía Pinillos, Felipe 
dc.date.accessioned2021-01-27T13:37:35Z
dc.date.available2021-01-27T13:37:35Z
dc.date.issued2020-11-27
dc.identifier.citationMolina-Molina A, Ruiz-Malagón EJ, Carrillo-Pérez F, Roche-Seruendo LE, Damas M, Banos O and García-Pinillos F (2020) Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment. Front. Physiol. 11:606287. [doi: 10.3389/fphys.2020.606287]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/66081
dc.descriptionThe authors wish to thank all participants for their assistance and to Irene Cantarero-Villanueva Ph.D. and Paula Postigo-Martín, of the Department of Physiotherapy (University of Granada, Spain), for providing us with their laboratories and materials so that this study could be carried out.es_ES
dc.description.abstractThe mDurance® system is an innovative digital tool that combines wearable surface electromyography (sEMG), mobile computing and cloud analysis to streamline and automatize the assessment of muscle activity. The tool is particularly devised to support clinicians and sport professionals in their daily routines, as an assessment tool in the prevention, monitoring rehabilitation and training field. This study aimed at determining the validity of the mDurance system for measuring muscle activity by comparing sEMG output with a reference sEMG system, the Delsys® system. Fifteen participants were tested during isokinetic knee extensions at three different speeds (60, 180, and 300 deg/s), for two muscles (rectus femoris [RF] and vastus lateralis [VL]) and two different electrodes locations (proximal and distal placement). The maximum voluntary isometric contraction was carried out for the normalization of the signal, followed by dynamic isokinetic knee extensions for each speed. The sEMG output for both systems was obtained from the raw sEMG signal following mDurance's processing and filtering. Mean, median, first quartile, third quartile and 90th percentile was calculated from the sEMG amplitude signals for each system. The results show an almost perfect ICC relationship for the VL (ICC > 0.81) and substantial to almost perfect for the RF (ICC > 0.762) for all variables and speeds. The Bland-Altman plots revealed heteroscedasticity of error for mean, quartile 3 and 90th percentile (60 and 300 deg/s) for RF and at mean and 90th percentile for VL (300 deg/s). In conclusion, the results indicate that the mDurance® sEMG system is a valid tool to measure muscle activity during dynamic contractions over a range of speeds. This innovative system provides more time for clinicians (e.g., interpretation patients' pathologies) and sport trainers (e.g., advising athletes), thanks to automatic processing and filtering of the raw sEMG signal and generation of muscle activity reports in real-time.es_ES
dc.language.isoenges_ES
dc.publisherFrontiers Mediaes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectWearableses_ES
dc.subjectElectromyography es_ES
dc.subjectKnee extensiones_ES
dc.subjectEMGes_ES
dc.subjectValidityes_ES
dc.subjectMuscle contractiones_ES
dc.subjectm-Healthes_ES
dc.titleValidation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessmentes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.3389/fphys.2020.606287
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España