dc.identifier.citationde la Torre, A.; Medina-Rodríguez, S.; Segura, J.C.; Fernández-Sánchez, J.F. Self-Referenced Multifrequency Phase-Resolved Luminescence Spectroscopy. Sensors 2020, 20, 5482. [DOI: https://doi.org/10.3390/s20195482]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/64549
dc.description.abstractPhase-resolved luminescence chemical sensors provide the analyte determination based on the estimation of the luminescence lifetime. The lifetime is estimated from an analysis of the amplitudes and/or phases of the excitation and emission signals at one or several modulation frequencies. This requires recording both the excitation signal (used to modulate the light source) and the emission signal (obtained from an optical transducer illuminated by the luminescent sensing phase). The excitation signal is conventionally used as reference, in order to obtain the modulation factor (the ratio between the emission and the excitation amplitudes) and/or the phase shift (the difference between the emission and the excitation phases) at each modulation frequency, which are used to estimate the luminescence lifetime. In this manuscript, we propose a new method providing the luminescence lifetimes (based either on amplitudes or phases) using only the emission signal (i.e., omitting the excitation signal in the procedure). We demonstrate that the luminescence lifetime can be derived from the emission signal when it contains at least two harmonics, because in this case the amplitude and phase of one of the harmonics can be used as reference. We present the theoretical formulation as well as an example of application to an oxygen measuring system. The proposed self-referenced lifetime estimation provides two practical advantages for luminescence chemical sensors. On one hand, it simplifies the instrument architecture, since only one analog-to-digital converter (for the emission signal) is necessary. On the other hand, the self-referenced estimation of the lifetime improves the robustness against degradation of the sensing phase or variations in the optical coupling, which reduces the recalibration requirements when the lifetimes are based on amplitudes.es_ES
dc.description.sponsorshipSpanish Ministry of Economy, Industry and Competitiveness CTQ2017-88079-P CTQ2014-53442-P BES-2009-026919es_ES
dc.description.sponsorshipSpanish Ministry of Economy, Industry and Competitiveness (Torres Quevedo Grants) PTQ-15-07922 PTQ-15-07912es_ES
dc.description.sponsorshipCEI BioTic Granada Campus CEIbioTIC14-2015es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectChemical sensores_ES
dc.subjectLuminescence spectroscopyes_ES
dc.subjectMultifrequencyes_ES
dc.subjectOxygen sensinges_ES
dc.subjectFrequency responsees_ES
dc.subjectQuadrature detectiones_ES
dc.subjectSelf-referenced analysises_ES
dc.titleSelf-Referenced Multifrequency Phase-Resolved Luminescence Spectroscopyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/s20195482


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España