Mostrar el registro sencillo del ítem

dc.contributor.authorMartínez Téllez, Borja Manuel 
dc.contributor.authorPerez-Bey, Alejandro
dc.contributor.authorSánchez-Delgado, Guillermo
dc.contributor.authorAcosta Manzano, Francisco Miguel
dc.contributor.authorCorral Pérez, Juan
dc.contributor.authorAmaro Gahete, Francisco José 
dc.contributor.authorAlcantara, Juan M.A.
dc.contributor.authorCastro-Piñero, José
dc.contributor.authorJiménez-Pavon, David
dc.contributor.authorLlamas Elvira, José Manuel 
dc.contributor.authorRuiz Ruiz, Jonatan 
dc.date.accessioned2020-05-21T11:21:47Z
dc.date.available2020-05-21T11:21:47Z
dc.date.issued2019-04-20
dc.identifier.citationB. Martinez-Tellez, et al. Concurrent validity of supraclavicular skin temperature measured with iButtons and infrared thermography as a surrogate marker of brown adipose tissue. Journal of Thermal Biology 82 (2019) 186–196 [https://doi.org/10.1016/j.jtherbio.2019.04.009]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/62171
dc.descriptionWe are grateful to Ms. Carmen Sainz-Quinn for assistance with the English language. We are grateful to Alberto Quesada-Aranda for helping with the development of the Temperatus software (Free trial in http://profth.ugr.es/temperatus).es_ES
dc.descriptionThis study is part of a Ph.D. Thesis conducted in the Biomedicine Doctoral Studies of the University of Granada, Spain.es_ES
dc.description.abstractBrown adipose tissue (BAT) thermogenic activity is commonly assessed with a positron emission tomography with computed tomography scan (PET/CT). This technique has several limitations and alternative techniques are needed. Supraclavicular skin temperature measured with iButtons and infrared thermography (IRT) has been proposed as an indirect marker of BAT activity. We studied the concurrent validity of skin temperature measured with iButtons vs. IRT and the association of supraclavicular skin temperature measured with iButtons and IRT with BAT. We measured skin temperature upon a shivering threshold test with iButtons and IRT in 6 different regions in 12 participants (n = 2 men). On a separate day, we determined supraclavicular skin temperature with an iButton and IRT after 2 h of a personalized cooling protocol. Thereafter, we quantified BAT volume and activity by PET/CT. We observed that the absolute differences between the devices were statistically different from 0 (all P < 0.05) after the shivering threshold test. Moreover, we did not find any association between supraclavicular skin temperature measured with iButtons or IRT and BAT 18F-FDG activity (r = −0.213; P = 0.530 and r = −0.079; P = 0.817). However, we observed a negative association of supraclavicular skin temperature measured by IRT with BAT 18F-FDG volume (r = −0.764; P = 0.006), but not with supraclavicular skin temperature measured with iButtons (r = −0.546; P = 0.082). In light of these results, we concluded that the measurement of skin temperature obtained by iButtons and IRT are not comparable. Furthermore, it seems that supraclavicular skin temperature is not associated with BAT 18F-FDG activity, but it appears to be negatively associated with BAT 18F-FDG volume in the case of IRT.es_ES
dc.description.sponsorshipThis study was supported by the Spanish Ministry of Economy and Competitiveness via the Fondo de Investigación Sanitaria del Instituto de Salud Carlos III (PI13/01393), Retos de la Sociedad (DEP2016-79512-R), PTA 12264-I, and European Regional Development Fund (ERDF), the Spanish Ministry of Education (FPU 13/04365, FPU14/04172, FPU15/05337, and FPU15/04059), by the Spanish Ministry of Science and Innovation-MINECO (RYC-2014-16938), the Fundación Iberoamericana de Nutrición (FINUT), the Redes Temáticas de Investigación Cooperativa RETIC (Red SAMID RD16/0022), the AstraZeneca HealthCare Foundation, the University of Granada Plan Propio de Investigación 2016 -Excellence actions: Unit of Excellence on Exercise and Health (UCEES) - and Plan Propio de Investigación 2018 - Programa Contratos-Puente, and the Junta de Andalucía, Consejería de Conocimiento, Investigación y Universidades (ERDF, ref. SOMM17/6107/UGR). This study is part of a Ph.D.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectBrown fates_ES
dc.subjectSkin temperaturees_ES
dc.subjectThermoregulationes_ES
dc.titleConcurrent validity of supraclavicular skin temperature measured with iButtons and infrared thermography as a surrogate marker of brown adipose tissuees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.1016/j.jtherbio.2019.04.009


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España