| dc.contributor.author | García Ramos, Amador | |
| dc.contributor.author | Janicijevic, Danica | |
| dc.contributor.author | González Hernández, Jorge M. | |
| dc.contributor.author | Keogh, Justin W. L. | |
| dc.contributor.author | Weakley, Jonathon | |
| dc.date.accessioned | 2020-04-15T11:45:40Z | |
| dc.date.available | 2020-04-15T11:45:40Z | |
| dc.date.issued | 2020-03-11 | |
| dc.identifier.citation | García-Ramos A, Janicijevic D, González-Hernández JM, Keogh JWL, Weakley J. 2020. Reliability of the velocity achieved during the last repetition of sets to failure and its association with the velocity of the 1-repetition maximum | es_ES |
| dc.identifier.uri | http://hdl.handle.net/10481/61254 | |
| dc.description.abstract | Background: This study aimed to determine the reliability of the velocity achieved
during the last repetition of sets to failure (Vlast) and the association of Vlast with the
velocity of the 1-repetition maximum (V1RM) during the paused and touch-and-go
bench press (BP) exercises performed in a Smith machine.
Methods: A total of 96 healthy men participated in this study that consisted of two
testing sessions. A single BP variant (paused BP or touch-and-go BP) was evaluated
on each session in a randomized order. Each session consisted of an incremental
loading test until reaching the 1RM, followed by two sets of repetitions to failure
against a load ranging from 75% to 90% of 1RM.
Results: The reliability of Vlast was unacceptable for both BP variants (CV > 18.3%,
ICC < 0.60). The correlations between V1RM and Vlast were small for the paused BP
(r = 0.18) and moderate for the touch-and-go BP (r = 0.37).
Conclusions: Although these results suggest that Vlast could be a better indicator
of the minimal velocity threshold than V1RM, the low reliability of Vlast and the
similar values of Vlast for both BP variants suggest that a standard V1RM should be
used to estimate the 1RM from the individualized load-velocity relationship. | es_ES |
| dc.description.sponsorship | This research was funded by the Universidad Católica de la Santísima Concepción
(DINREG 09/2019). | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | PeerJ | es_ES |
| dc.rights | Atribución 3.0 España | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es/ | * |
| dc.subject | Bench press | es_ES |
| dc.subject | Linear position transducer | es_ES |
| dc.subject | Minimal velocity threshold | es_ES |
| dc.subject | Strength testing | es_ES |
| dc.subject | Velocity-based training | es_ES |
| dc.title | Reliability of the velocity achieved during the last repetition of sets to failure and its association with the velocity of the 1-repetition maximum | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | 10.7717/peerj.8760 | |