Mostrar el registro sencillo del ítem

dc.contributor.authorMelchor, Juan
dc.contributor.authorSoto, Juan M.
dc.contributor.authorLópez Ruiz, Elena
dc.contributor.authorSuárez Medina, Francisco Javier 
dc.contributor.authorJiménez, Gema
dc.contributor.authorAntich Acedo, Cristina
dc.contributor.authorPerán, Macarena
dc.contributor.authorMarchal Corrales, Juan Antonio 
dc.contributor.authorRus Carlborg, Guillermo 
dc.date.accessioned2020-02-20T10:48:18Z
dc.date.available2020-02-20T10:48:18Z
dc.date.issued2019
dc.identifier.citationMelchor, J., Soto, J. M., López-Ruiz, E., Suarez, J., Jiménez, G., Antich, C., ... & Rus, G. (2019). High-Resolution Strain Measurement for Biomechanical Parameters Assessment in Native and Decellularized Porcine Vessels. Mathematical Problems in Engineering, 2019.es_ES
dc.identifier.urihttp://hdl.handle.net/10481/59787
dc.description.abstractDecellularized vascular scaffolds are promising materials for vessel replacements. However, despite the natural origin of decellularized vessels, issues such as biomechanical incompatibility, immunogenicity risks, and the hazards of thrombus formation still need to be addressed. In this study, we assess the mechanical properties of two groups of porcine carotid blood vessels: (i) native arteries and (ii) decellularized arteries.The biomechanical properties of both groups (n = 10, sample size of each group) are determined by conducting uniaxial and circumferential tensile tests by using an ad hoc and lab-made device comprising a peristaltic pump that controls the load applied to the sample. This load is regularly incremented (8 grams per cycle with a pause of 20 seconds after each step) while keeping the vessels continuously hydrated. The strain is measured by an image cross-correlation technique applied on a high-resolution video. The mechanical testing analyses of the arteries revealed significant differences in burst pressure between the native (1345.08±96.58 mbar) and decellularized (1067.79±112.13 mbar) groups.Moreover, decellularized samples show a significantly lower maximum load at failure (15.78±0.79 N) in comparison with native vessels (19.42±0.80 N). Finally, the average ultimate circumferential tensile also changes between native (3.71±0.37 MPa) and decellularized (2.93±0.18 MPa) groups. This technique is able to measure the strain in the regime of large displacements and enables high-resolution image of the local strains, thus providing a valuable tool for characterizing several biomechanical parameters of the vessels also applicable to other soft tissue presenting hyperelastic behaviours.es_ES
dc.description.sponsorshipThis research was supported by the Ministry of Education [DPI2014-51870-R, DPI2017-85359-R, UNGR15-CE- 3664, and PI16/00339], Junta de Andalucía [PIN-0030- 2017, PIN-0379, CTS-6568, and PI-0107-2017 Projects], and University of Granada [PP2017-PIP2019]. Ministerio de Economía y Competitividad is also acknowledged for funding the project [TEC2014-57394-P] and MNat Scientific Unit of Excellence (UCE.PP2017.03).es_ES
dc.language.isoenges_ES
dc.publisherHindawies_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.titleHigh-Resolution Strain Measurement for Biomechanical Parameters Assessment in Native and Decellularized Porcine Vesselses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1155/2019/2402606


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España