Mostrar el registro sencillo del ítem

dc.contributor.authorHermoso, Martín
dc.contributor.authorGarcía-Ruiz, María Jesús
dc.contributor.authorOsorio Robles, Francisco 
dc.date.accessioned2019-04-05T11:52:49Z
dc.date.available2019-04-05T11:52:49Z
dc.date.issued2018-10-12
dc.identifier.citationHermoso, M.; García-Ruiz, Mª.J.; Osorio, F. Efficiency of Flood Control Measures in a Sewer System Located in the Mediterranean Basin. Water 2018, 10, 1437; doi:10.3390/w10101437es_ES
dc.identifier.issn2073-4441
dc.identifier.urihttp://hdl.handle.net/10481/55357
dc.description.abstractPollution induced by surface runoff in urban areas constitutes a significant problem. The adoption of control measures aimed at improving the quality of recipient water bodies is a fundamental issue in the management of Mediterranean Basin sewer systems. Previous research in Mediterranean areas using small virtual basins has shown that rainfall regimes have a limited impact on the pollutant load and discharge flowing into a receiving body. The aim of our research was to identify a sizing methodology for stormwater tanks located in the Mediterranean Basin. To achieve this, a numerical model of a sewer system, located in the Southern Iberian Peninsula, was developed. Different patterns related to peak periods of rainfall were considered. Furthermore, efficiency indices were used to evaluate and compare the effects of having a stormwater tank in the system. In our study (which considered a real area), significantly varied values were obtained for the pollution load removal rate (η) and the receiver overflow rate (θ). We nevertheless observed that, in our catchment, at a specific volume of V = 60 m3/ha, h and θ reached constant values without experiencing any significant improvement (η = 0.673 and θ = 0.133). Based on our model, this volume was proposed for the stormwater tank. The ATV (German Association forWater Pollution Control) A 128 standard was applied in order to validate the results, and the specific volume obtained (V = 60 m3/ha) matched with the one proposed. Thus, our proposed methodology is simple and different, and it is very easy to apply by obtaining the values of the efficiency indices η and θ through the development of a Storm Water Management Model (SWMM).es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectCombined sewer overflowses_ES
dc.subjectControl measureses_ES
dc.subjectSimulation modelses_ES
dc.subjectStormwater tankses_ES
dc.titleEfficiency of Flood Control Measures in a Sewer System Located in the Mediterranean Basines_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España