dc.contributor.author | Toledano Pérez, Manuel | |
dc.contributor.author | Toledano Osorio, Manuel | |
dc.contributor.author | Guerado, Enrique | |
dc.contributor.author | Caso, Enrique | |
dc.contributor.author | Osorio Ruiz, María Estrella | |
dc.contributor.author | Osorio Ruiz, Raquel | |
dc.date.accessioned | 2018-09-25T11:31:00Z | |
dc.date.available | 2018-09-25T11:31:00Z | |
dc.date.issued | 2018 | |
dc.identifier.citation | Toledano M, Toledano-Osorio M, Guerado E, Caso E, Osorio E, Osorio R. Assessing bone quality through mechanical properties in postmenopausal trabecular bone. Injury. 2018 Sep;49 Suppl 2:S3-S10. doi: 10.1016/j.injury.2018.07.035. | es_ES |
dc.identifier.uri | http://hdl.handle.net/10481/52909 | |
dc.description.abstract | Background: The inner structure of trabecular bone is a result of structural optimisation
provided by remodeling processes. Changes in hormonal status related to menopause
cause bone tissue loss and micro-architectural deterioration with a consequent
susceptibility to fracture. Accumulation of micro-damage in bone, as a function of the
rate of production and rate of repair, underlies the development of stress fractures,
increasing fragility associated to age and osteoporosis, especially in transmenopausal
women. Patients and Methods: Quasi-static and nano-dynamic mechanical
characterisation were undertaken in trabecular bone from femoral neck biopsies of
postmenopausal women. AFM complementary studies were performed to determine
nano-roughness (SRa) and the fibrils width of collagen. Nanoindentations were used to
quantify transmenopausal changes in intrinsic mechanical properties of trabecular bone:
hardness (Hi), modulus of Young (Ei), complex modulus (E*), tan delta (δ), storage
modulus (E') and loss modulus (E"). Results: As result of the quasi-static measurements,
0.149 (0.036) GPa and 2.95 (0.73) GPa of Hi and Ei were obtained, respectively. As result
of the nano-dynamic measurements, 17.94 (3.15), 0.62 (0.10), 13.79 (3.21 and 6.39 (1.28)
GPa of E*, tan (δ), E' and E" were achieved, respectively. 101.07 SRa and 831.28 nm of
fibrils width were additionally obtained. Conclusion: This study poses a first approach to
the measurement of bone quality in postmenopausal trabecular bone by combining quasistatic,
nano-DMA analysis and tribology of dentin surface through AFM characterization | es_ES |
dc.description.sponsorship | Project MAT2017-85999-P supported by the Ministry of Economy and Competitiveness
(MINECO) and European Regional Development Fund (FEDER). | es_ES |
dc.language.iso | eng | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Trabecular bone | es_ES |
dc.subject | static | es_ES |
dc.subject | dynamic | es_ES |
dc.subject | mechanic | es_ES |
dc.subject | menopause | es_ES |
dc.title | Assessing bone quality through mechanical properties in postmenopausal trabecular bone. | es_ES |
dc.type | journal article | es_ES |
dc.rights.accessRights | open access | es_ES |
dc.identifier.doi | 10.1016/j.injury.2018.07.035. | |