Mostrar el registro sencillo del ítem

dc.contributor.authorCampos, Fernando
dc.contributor.authorGarzón Bello, Ingrid Johanna 
dc.contributor.authorRodríguez, Ismael
dc.contributor.authorMartín Piedra, Miguel Ángel 
dc.date.accessioned2018-05-07T10:49:08Z
dc.date.available2018-05-07T10:49:08Z
dc.date.issued2016-04
dc.identifier.citationCampos, Fernando, et. al. Evaluación de la viabilidad celular en constructos tisulares. Estudio preliminar. Actual. Med. 2016; 101: (797): 13-17 [http://hdl.handle.net/10481/50563]es_ES
dc.identifier.urihttp://hdl.handle.net/10481/50563
dc.descriptionLos autores agradecen a las Profesoras Allice Warley (King’s Co- llege, London) y María del Carmen Sánchez-Quevedo (Universidad de Granada) por el asesoramiento recibido en el desarrollo de las técnicas de microscopía electrónica analítica por energía dispersiva de rayos-X.es_ES
dc.description.abstractObjetivo: Aplicar la microscopia electrónica analítica por energía dispersiva de rayos X a la evaluación de la viabilidad celular en constructos tisulares de fibrina agarosa y determinar la viabilidad celular en el seno del constructo Material y Métodos: Se evalúan fibroblastos aislados y fibroblastos en el seno del constructo a los 7 y 21 días con la técnica de Live/Dead y de microscopia electrónica analítica por energía dispersiva de rayos X. Resultados: El estudio demuestra que la aplicación de la técnica es factible y que la viabilidad es elevada en los constructos a los 21 días sin que existan signo de apoptosis en la población celular. Conclusión: La microscopia electrónica analítica por energía dispersiva de rayos X permite evaluar la viabilidad celular en los constructos tisulares y establecer un control de calidad más exigente para su aplicación terapéutica.es_ES
dc.description.abstractObjective: Apply X-ray microanalytical electron microscopy to evaluate cell viability in fibrin agarose tissue constructs and determine cell viability within the construct. Material and Methods: Isolated fibroblasts and fibroblasts within the construct are evaluated at 7 and 21 days with the technique of Live/Dead and with X-ray microanalytical electron microscopy. Results: The study shows that the application of the technique is feasible that viability is high in the constructs at 21 days without sign of apoptosis in the cell population. Conclusion: X-ray microanalytical electron microscopy allows the evaluation of cell viability in tissue constructs and establish a more demanding quality control for therapeutic application.es_ES
dc.language.isospaes_ES
dc.publisherReal Academia de Medicina y Cirugía de Andalucía Oriental; Universidad de Granadaes_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/*
dc.subjectViabilidad celulares_ES
dc.subjectConstructoes_ES
dc.subjectMicroanálisis es_ES
dc.subjectCell viabilityes_ES
dc.subjectConstructes_ES
dc.subjectMicroanalysises_ES
dc.titleEvaluación de la viabilidad celular en constructos tisulares. Estudio preliminares_ES
dc.title.alternativeCell viability evaluation in tissue constructs. A preliminary studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.15568/am.2016.797.or02


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-CompartirIgual 3.0 España