dc.identifier.citationCallejas Zafra, A.M.; et al. Performance Study of a Torsional Wave Sensor and Cervical Tissue Characterization. Sensors, 17(9): 2078 (2017). [http://hdl.handle.net/10481/48480]es_ES
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10481/48480
dc.description.abstractA novel torsional wave sensor designed to characterize mechanical properties of soft tissues is presented in this work. Elastography is a widely used technique since the 1990s to map tissue stiffness. Moreover, quantitative elastography uses the velocity of shear waves to achieve the shear stiffness. This technique exhibits significant limitations caused by the difficulty of the separation between longitudinal and shear waves and the pressure applied while measuring. To overcome these drawbacks, the proposed torsional wave sensor can isolate a pure shear wave, avoiding the possibility of multiple wave interference. It comprises a rotational actuator disk and a piezoceramic receiver ring circumferentially aligned. Both allow the transmission of shear waves that interact with the tissue before being received. Experimental tests are performed using tissue mimicking phantoms and cervical tissues. One contribution is a sensor sensitivity study that has been conducted to evaluate the robustness of the new proposed torsional wave elastography (TWE) technique. The variables object of the study are both the applied pressure and the angle of incidence sensor–phantom. The other contribution consists of a cervical tissue characterization. To this end, three rheological models have fit the experimental data and a static independent testing method has been performed. The proposed methodology permits the reconstruction of the mechanical constants from the propagated shear wave, providing a proof of principle and warranting further studies to confirm the validity of the results.en_EN
dc.description.sponsorshipThis research was supported by the Ministry of Education DPI2014-51870-R, DPI2010-17065 and UNGR15-CE-3664, Ministry of Health DTS15/00093 and PI16/00339, and Junta de Andalucía P11-CTS-8089 projects. Modesto T. López-López acknowledges financial support by the project FIS2013-41821-R (Ministry of Economy and Competitiveness, co-funded by the ERDF, European Union). We acknowledge the collaboration of the members of the Anatomical Pathology Unit of the University Hospital Complex of Granada. Finally, Antonio Callejas is grateful to the University of Granada for the award of an PhD fellowship.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.subjectTorsional wave sensoren_EN
dc.subjectTissue mimicking phantomen_EN
dc.subjectCervical tissueen_EN
dc.subjectRheological modelen_EN
dc.subjectRheometry experimenten_EN
dc.subjectSensitivty studyen_EN
dc.subjectComplex shear modulusen_EN
dc.titlePerformance Study of a Torsional Wave Sensor and Cervical Tissue Characterizationen_EN