Mostrar el registro sencillo del ítem

dc.contributor.authorHernández-Cortés, Pedro
dc.contributor.authorMonje, Alberto
dc.contributor.authorGalindo Moreno, Pablo Antonio 
dc.contributor.authorCatena Martínez, Andrés 
dc.contributor.authorOrtega-Oller, Inmaculada
dc.contributor.authorSalas-Pérez, José
dc.contributor.authorMesa Aguado, Francisco Luis 
dc.contributor.authorGómez Sánchez, Rafael
dc.contributor.authorAguilar Peña, Mariano 
dc.contributor.authorAguilar Peña, David 
dc.contributor.authorO'Valle Ravassa, Francisco Javier 
dc.date.accessioned2015-04-09T11:03:39Z
dc.date.available2015-04-09T11:03:39Z
dc.date.issued2014
dc.identifier.citationHernández-Cortés, P.; et al. An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability. BioMed Research International, 2014: 535929 (2014). [http://hdl.handle.net/10481/35486]es_ES
dc.identifier.issn2314-6133
dc.identifier.issn2314-6141
dc.identifier.urihttp://hdl.handle.net/10481/35486
dc.description.abstractObjective. This study was designed to explore relationships of resonance frequency analysis (RFA)—assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. Material and Methods. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) ( ) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) ( ). Sixty  mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. Results. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) ( ), but not of the implants ( ) or of the interaction of the two factors ( ). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified ( ) heads than in fresh ( ) or fixated ( ) heads (both ). The ISQ score (fresh) was significantly higher for those in OA ( ) versus OP ( ) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results ( in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both ). Conclusion. Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies.es_ES
dc.description.sponsorshipThis investigation was partially supported by Research Group no. CTS-138 (Junta de Andalucía, Spain).es_ES
dc.language.isoenges_ES
dc.publisherHindawi Publishing Corporationes_ES
dc.subjectResonance frequency analysis (RFA)es_ES
dc.subjectDental implants es_ES
dc.subjectHuman femoral headses_ES
dc.titleAn Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stabilityes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1155/2014/535929


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem