Mostrar el registro sencillo del ítem

dc.contributor.authorGarcía Caridad, Margaritaes_ES
dc.contributor.authorFernández, Mirnaes_ES
dc.contributor.authorCastiñeira, Mirtaes_ES
dc.contributor.authorMartínez, Vivianes_ES
dc.contributor.authorLópez Orestes, Daríoes_ES
dc.contributor.authorNogueira, Antonioes_ES
dc.date.accessioned2015-01-28T11:09:54Z
dc.date.available2015-01-28T11:09:54Z
dc.date.issued2014
dc.identifier.citationGarcía Caridad, M.; et al. Validación de un método cromatográfico aplicable al control de calidad y estudio de estabilidad del pool de aceite hígado de tiburón microencapsulado. Ars Pharm, 55(2): 19-24 (2014). [http://hdl.handle.net/10481/34432]es_ES
dc.identifier.issn0004-2927
dc.identifier.issn2340-9894
dc.identifier.urihttp://hdl.handle.net/10481/34432
dc.description.abstractObjetivo: Se validó un método cromatográfico para la determinación del contenido de vitamina A en el pool de aceite microencapsulado de hígado de tiburón. Material y Método: Los parámetros evaluados se correspondieron con lo establecido internacionalmente para técnicas cuantitativas como: especificidad, linealidad, exactitud, precisión, robustez y límites de detección y cuantificación. El método se basó en la separación de la vitamina A, a través de una columna cromatográfica Lichrosorb RP – 18, a una longitud de onda de 325 nm, empleando una fase móvil compuesta por metanol: agua, en proporción 90:10, y la cuantificación de la misma frente a una muestra de referencia empleando el método del estándar externo. Resultados: Se demostró que el procedimiento desarrollado, fue lo suficientemente lineal, con un límite de detección de 2 μg/mL y 6 μg/mL como límite de cuantificación, específico, preciso, exacto y robusto para la determinación del contenido de vitamina A en el pool de aceite microencapsulado.Conclusiones: La determinación del contenido de vitamina A en el pool de aceite de hígado de tiburón microencapsulado, a través de un método por cromatografía líquida de alta resolución, resultó específico, lineal, preciso, exacto y robusto, aplicable al control de calidad y estudio de estabilidad.es_ES
dc.description.abstractAim: The purpose of this study was to validate, in accordance with international standards, a chromatographic method to determine the vitamin A in the pool of shark liver oil microencapsulated. Materials and Methods: The valued parameters belonged together with what settles down internationally for technical quantitative, among those that we can mention: specificity, lineality, accuracy, precision, robustness and detection and quantification limits. The method based on the separation from the vitamin A to inclination a chromatographic column Lichrosorb RP - 18 to a wavelength of 325 nm, using a mobile phase composed by methanol: water, of proportion 90:10, and the quantification of the same ones in front of referee samples using the method of the external standard. Results: It was demonstrated that the developed procedure, was the sufficiently lineal thing, with a detection limit of 2 μg/mL and 6 μg/mL like quantification limit, specific, precise, exact and robust for the determination of the vitamin A content in the pool of microencapsulated oil, for what can be an employee in the quality control and stability study. Conclusions: The determination of the vitamin A content in the microencapsulated pool of shark liver oil, through a method for high resolution liquid chromatography, was specific, lineal, precise, exact and robust, for quality control and stability study.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Granada, Facultad de Farmaciaes_ES
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivs 3.0 Licensees_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es_ES
dc.subjectAceite de hígado de pescadoes_ES
dc.subjectCromatografía líquidaes_ES
dc.subjectEstudio de validaciónes_ES
dc.subjectmicroencapsulaciónes_ES
dc.subjectVitamina Aes_ES
dc.subjectChromatographyes_ES
dc.subjectHigh pressure liquides_ES
dc.subjectMicroencapsulationes_ES
dc.subjectValidation studieses_ES
dc.subjectVitamin Aes_ES
dc.titleValidación de un método cromatográfico aplicable al control de calidad y estudio de estabilidad del pool de aceite hígado de tiburón microencapsuladoes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License