| dc.contributor.author | Martínez Olmos, Antonio | |
| dc.contributor.author | Ballesta Claver, Julio | |
| dc.contributor.author | Palma López, Alberto José | |
| dc.contributor.author | Valencia Mirón, María del Carmen | |
| dc.contributor.author | Capitán Vallvey, Luis Fermín | |
| dc.date.accessioned | 2013-10-21T10:59:59Z | |
| dc.date.available | 2013-10-21T10:59:59Z | |
| dc.date.issued | 2009 | |
| dc.identifier.citation | Martínez Olmos, A.; et al. A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination. Sensors, 9(10): 7694-7710 (2009). [http://hdl.handle.net/10481/28498] | es_ES |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.uri | http://hdl.handle.net/10481/28498 | |
| dc.description.abstract | A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidation of luminol, with all the reagents immobilized in a Methocel membrane. The membrane composition and reaction conditions have been optimized to obtain adequate sensitivity. The luminometer is based on a large silicon photodiode as detector and includes a programmable potentiostat to initialize the chemical reaction and signal processing circuitry, designed to acquire a low level photocurrent with offset cancelation, low pass filtering for noise attenuation and adjustable gain up to 1012 V/A. The one-shot biosensor responds to lactate rapidly, with an acquisition time of 2.5 min, obtaining a linear dependence from 8 × 10−6 to 2 × 10−4 M, a detection limit of 2.4 × 10−6 M and a sensor-to-sensor reproducibility (relative standard deviation, RSD) of around 7–10 % at the medium level of the range. | es_ES |
| dc.description.sponsorship | We acknowledge financial support from Ministerio de Educación y Ciencia, Dirección General de
Enseñanza Superior (Spain) (Projects CTQ2005-09060-CO2-01, CTQ2005-09060-CO2-02) and from
Junta de Andalucía (Projects P06-FQM-01467 and P08-FQM-3535). | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | MDPI | es_ES |
| dc.rights | Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ | es_ES |
| dc.subject | Portable instrument | es_ES |
| dc.subject | Microcontroller | es_ES |
| dc.subject | Electrochemiluminescence measurement | es_ES |
| dc.subject | Disposable biosensor | es_ES |
| dc.subject | Lactate determination | es_ES |
| dc.title | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | 10.3390/s91007694 | es_ES |