Safety assessment of the Torre de la Vela in la Alhambra, Granada, Spain: The role of on site works

[PDF] Artículo principal (1.111Mb)
Identificadores
URI: https://hdl.handle.net/10481/109287
DOI: 10.1016/j.engstruct.2022.114443
ISSN: 0141-0296
Exportar
RISRefworksMendeleyBibtex
Estadísticas
View Usage Statistics
Metadata
Show full item record
Author
Vuoto, Annalaura; Ortega, Javier; Lorenço, Paulo B.; Suárez Medina, Francisco Javier; Núñez, Antonieta Claudia
Editorial
Elsevier
Materia
Rammed earth
 
Non-destructive testing
 
Numerical modeling
 
Seismic safety assessment
 
Alhambra
 
UNESCO World Heritage Site
 
Laser scanning
 
Date
2022-08
Referencia bibliográfica
Vuoto, A., Ortega, J., Lourenço, P. B., Javier Suárez, F., & Claudia Núñez, A. (2022). Safety assessment of the Torre de la Vela in la Alhambra, Granada, Spain: The role of on site works. Engineering Structures. Volume 264, 1 August 2022, 114443. http://doi.org/10.1016/j.engstruct.2022.114443
Sponsorship
University of Granada, ref. UCPP2018-01; Patronato de La Alhambra y Generalife
Abstract
The Alhambra is a UNESCO World Heritage Site located in Granada, which is the area with the highest seismic hazard in Spain. The present work focuses on the seismic safety evaluation of the Torre de la Vela, the main tower of the Alcazaba, the fortress of the Alhambra and the first area of the citadel built in the 13th century. The safety evaluation is carried out using finite element modeling and nonlinear static analyses. In a first phase, a numerical model of the tower was prepared based solely on bibliographic review and a first set of analyses was carried out. In a second phase, the monument was visited and a detailed survey including non-destructive testing was carried out. A second set of analyses was performed using an updated model calibrated with experimental results and the seismic safety assessment was carried out. The results are systematically compared and highlight the importance of on-site works for a correct safety assessment of historic structures.
Collections
  • DMEIH - Artículos

My Account

LoginRegister

Browse

All of DIGIBUGCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectFinanciaciónAuthor profilesThis CollectionBy Issue DateAuthorsTitlesSubjectFinanciación

Statistics

View Usage Statistics

Servicios

Pasos para autoarchivoAyudaLicencias Creative CommonsSHERPA/RoMEODulcinea Biblioteca UniversitariaNos puedes encontrar a través deCondiciones legales

Contact Us | Send Feedback