Mostrar el registro sencillo del ítem

dc.contributor.authorJiménez-López, Concepción
dc.contributor.authorRodríguez-Navarro, Alejandro
dc.contributor.authorPérez-González, Teresa
dc.contributor.authorCarrillo Rosúa, Francisco Javier 
dc.contributor.authorBoyce, Adrian J.
dc.contributor.authorRomanek, Christopher S.
dc.date.accessioned2015-04-06T12:18:13Z
dc.date.available2015-04-06T12:18:13Z
dc.date.issued2007
dc.identifier.citationJiménez-López, C.; Rodríguez-Navarro, A.; Pérez-González, T.; Carrillo Rosúa, J.; Boyce, A.J.; Romanek, C.S. New method for separation of magnetite from rock samples for oxygen isotope analysis. European Journal of Mineralogy, 19(5): 717-722 (2007). [http://hdl.handle.net/10481/35405]es_ES
dc.identifier.issn0935-1221
dc.identifier.issn1617-4011
dc.identifier.urihttp://hdl.handle.net/10481/35405
dc.descriptionEste artículo ha sido publicado en la Revista European Journal of Mineralogy, correspondiendo la presente versión a un preprintes_ES
dc.description.abstractA new procedure is described to separate magnetite from milligram sized samples of crushed rock for oxygen isotope analysis. This method is based on magnetic separation of magnetite after heating the mixture to a temperature that exceeds the Curie point for other magnetic minerals in a sample. The relatively low temperature of this procedure (350º C) does not induce any reaction between magnetic mineral nor does it alter the isotope composition of magnetite. This procedure was tested on samples containing known percentages of magnetite and pyrrhotite. The percentage of magnetite in a sample was increased by 10-20 % through successive enrichment cycles until a pure magnetite separate was achieved. The separation should be performed before measuring the oxygen isotope composition of the magnetic fraction of a rock sample by laser ablation, because the presence of contaminating phases such as pyrrhotite may cause unwanted isotope partitioning of the oxygen released during fluorination. Our data show that contamination of a magnetite sample, even with a non O-bearing phase, can lead to systematically misleading O isotope data in a standard total laser fluorination system. Enrichment of the apparent magnetite value is indicated, possibly as a result of the formation of an O-S-bearing phase which escapes the influence of the plasma created by the laser.es_ES
dc.description.sponsorshipThis research was supported by research projects CGL2004-03910, RNM2003-07375 from the MEC (Spain) and by the U.S. Department of Energy through Financial Assistance Award No. DE-FC09-96-SR18546 to the University of Georgia Research Foundation. CJL wishes to thank the Fulbright/MEC Program. SUERC is supported by NERC and the Scottish Universities consortium. AJB is funded by NERC Scientific Services' support of the Isotope Community Support Facility at SUERC.es_ES
dc.language.isoenges_ES
dc.publisherE. Schweizerbart Science Publisherses_ES
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivs 3.0 Licensees_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es_ES
dc.subjectMagnetitees_ES
dc.subjectPyrrhotitees_ES
dc.subjectOxygen isotopees_ES
dc.subjectMineral separationes_ES
dc.titleNew method for separation of magnetite from rock samples for oxygen isotope analysises_ES
dc.typeinfo:eu-repo/semantics/preprintes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.1127/0935-1221/2007/0019-1761


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License