Mostrar el registro sencillo del ítem

dc.contributor.authorOlivares, Alberto
dc.contributor.authorRuiz-García, Gonzalo
dc.contributor.authorOlivares Ruiz, Gonzalo 
dc.contributor.authorGorriz Sáez, Juan Manuel 
dc.contributor.authorRamírez Pérez De Inestrosa, Javier 
dc.date.accessioned2014-01-17T09:14:12Z
dc.date.available2014-01-17T09:14:12Z
dc.date.issued2013
dc.identifier.citationOlivares, A.; et al. Automatic Determination of Validity of Input Data Used in Ellipsoid Fitting MARG Calibration Algorithms. Sensors, 13(9): 11797-11817 (2013). [http://hdl.handle.net/10481/29879]es_ES
dc.identifier.issn1424-8220
dc.identifier.otherdoi: 10.3390/s130911797
dc.identifier.urihttp://hdl.handle.net/10481/29879
dc.description.abstractEllipsoid fitting algorithms are widely used to calibrate Magnetic Angular Rate and Gravity (MARG) sensors. These algorithms are based on the minimization of an error function that optimizes the parameters of a mathematical sensor model that is subsequently applied to calibrate the raw data. The convergence of this kind of algorithms to a correct solution is very sensitive to input data. Input calibration datasets must be properly distributed in space so data can be accurately fitted to the theoretical ellipsoid model. Gathering a well distributed set is not an easy task as it is difficult for the operator carrying out the maneuvers to keep a visual record of all the positions that have already been covered, as well as the remaining ones. It would be then desirable to have a system that gives feedback to the operator when the dataset is ready, or to enable the calibration process in auto-calibrated systems. In this work, we propose two different algorithms that analyze the goodness of the distributions by computing four different indicators. The first approach is based on a thresholding algorithm that uses only one indicator as its input and the second one is based on a Fuzzy Logic System (FLS) that estimates the calibration error for a given calibration set using a weighted combination of two indicators. Very accurate classification between valid and invalid datasets is achieved with average Area Under Curve (AUC) of up to 0.98.es_ES
dc.description.sponsorshipThis work was partly supported by the MICINN under the TEC2012-34306 project, the MEEC under the TIN2012-32039 (hpMooN) and the Consejería de Innovación, Ciencia y Empresa (Junta de Andalucía, Spain) under the Excellence Projects P09-TIC-4530 and P11-TIC-7103.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivs 3.0 Licensees_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es_ES
dc.subjectCalibration es_ES
dc.subjectAccelerometeres_ES
dc.subjectMagnetometeres_ES
dc.subjectMARG (Magnetic Angular Rate and Gravity)es_ES
dc.subjectMEMS (Microelectromechanical)es_ES
dc.subjectAutomatices_ES
dc.subjectValidationes_ES
dc.subjectFuzzyes_ES
dc.subjectFLS (Fuzzy Logic System)es_ES
dc.subjectThresholdinges_ES
dc.titleAutomatic Determination of Validity of Input Data Used in Ellipsoid Fitting MARG Calibration Algorithmses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License