Mostrar el registro sencillo del ítem

dc.contributor.authorGutiérrez Fernández, José 
dc.contributor.authorLara, A.
dc.contributor.authorBautista, M.F.
dc.contributor.authorLuna Del Castillo, Juan De Dios 
dc.contributor.authorPolo, P.
dc.contributor.authorMiranda, C.
dc.contributor.authorNavarro, J.M.
dc.date.accessioned2024-03-13T10:25:52Z
dc.date.available2024-03-13T10:25:52Z
dc.date.issued2012-09-01
dc.identifier.citationGutiérrez-Fernández J, Lara A, Bautista MF, de Dios Luna J, Polo P, Miranda C, Navarro JM. Performance of the Sysmex UF1000i system in screening for significant bacteriuria before quantitative culture of aerobic/facultative fast-growth bacteria in a reference hospital. J Appl Microbiol. 2012 Sep;113(3):609-14. DOI: 10.1111/j.1365-2672.2012.05369.xes_ES
dc.identifier.urihttps://hdl.handle.net/10481/89957
dc.description.abstractObjective: To evaluate the performance of the Sysmex UF1000i automatic urine screening system in the quantitative culture of fast-growth aerobic/facultative bacteria. Methods and results: A standard procedure was used to recover fast-growth aerobic/facultative micro-organisms in 1225 samples, applying (Sysmex(®)) flow cytometry for parallel bacteria and leucocyte counts. According to the area under the receiver operating characteristic curve, the optimal cut-off values to detect bacteriuria >10(5) colony forming units (CFU) ml(-1) were 690/μl for bacteria and 38/μl for leucocytes (sensitivity, 92%; specificity, 65%; positive predictive value [PPV], 39%; and negative predictive value [NPV], 97%). The use of a single cut-off point of 150 bacteria μl(-1) to detect significant bacteriuria of >10(5) CFU ml(-1) or of ≥10(4) CFU ml(-1) plus leucocyturia obtained similar results (sensitivity, 89%; specificity, 54%; PPV, 31%; and NPV, 96%) and allowed 45.7% of the samples to be rapidly excluded. Conclusions: The Sysmex UF1000i system can be adapted for bacteriuria screening by the use of an appropriate cut-off point. Significance and impact of the study: This screening system significantly reduces the workload and produces very few false positives and negatives.es_ES
dc.language.isoenges_ES
dc.publisherOxford University Presses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectBacteriuriaes_ES
dc.subjectCytometryes_ES
dc.subjectSysmexes_ES
dc.subjectUrinary tract infectiones_ES
dc.subjectUrine es_ES
dc.titlePerformance of the Sysmex UF1000i system in screening for significant bacteriuria before quantitative culture of aerobic/facultative fast-growth bacteria in a reference hospitales_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.1111/j.1365-2672.2012.05369.x
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional