Mostrar el registro sencillo del ítem

dc.contributor.authorMelchor Rodríguez, Juan Manuel es_ES
dc.contributor.authorMuñoz Beltrán, Rafael es_ES
dc.contributor.authorRus Carlborg, Guillermo es_ES
dc.date.accessioned2017-07-27T11:36:01Z
dc.date.available2017-07-27T11:36:01Z
dc.date.issued2017-06-15
dc.identifier.citationMelchor Rodríguez, J.M.; Muñoz Beltrán, R.; Rus Carlborg, G. Torsional Ultrasound Sensor Optimization for Soft Tissue Characterization. Sensors, 17(6): 1402 (2017). [http://hdl.handle.net/10481/47291]es_ES
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10481/47291
dc.description.abstractTorsion mechanical waves have the capability to characterize shear stiffness moduli of soft tissue. Under this hypothesis, a computational methodology is proposed to design and optimize a piezoelectrics-based transmitter and receiver to generate and measure the response of torsional ultrasonic waves. The procedure employed is divided into two steps: (i) a finite element method (FEM) is developed to obtain a transmitted and received waveform as well as a resonance frequency of a previous geometry validated with a semi-analytical simplified model and (ii) a probabilistic optimality criteria of the design based on inverse problem from the estimation of robust probability of detection (RPOD) to maximize the detection of the pathology defined in terms of changes of shear stiffness. This study collects different options of design in two separated models, in transmission and contact, respectively. The main contribution of this work describes a framework to establish such as forward, inverse and optimization procedures to choose a set of appropriate parameters of a transducer. This methodological framework may be generalizable for other different applications.en_EN
dc.description.sponsorshipThis research was supported by the Intituto de Salud Carlos III, projects DTS15-00093 (EU-FEDER), UNGRIS-CE-3664, the Ministry of Education DPI2014-51870-R and Junta de Andalucia for projects P11-CTS-8089 and GGI3000IDIB.en_EN
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.subjectTorsional ultrasounden_EN
dc.subjectProbability of detectionen_EN
dc.subjectSoft tissue mechanicsen_EN
dc.subjectFinite element method en_EN
dc.subjectOptimizationen_EN
dc.subjectInverse problemen_EN
dc.titleTorsional Ultrasound Sensor Optimization for Soft Tissue Characterizationen_EN
dc.typeinfo:eu-repo/semantics/articleen_EN
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen_EN
dc.identifier.doi10.3390/s17061402


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem