Mostrar el registro sencillo del ítem

dc.contributor.authorBaños Legrán, Oresti es_ES
dc.contributor.authorMoral Muñoz, José Antonioes_ES
dc.contributor.authorDíaz-Reyes, Ignacioes_ES
dc.contributor.authorArroyo Morales, Manuel es_ES
dc.contributor.authorDamas Hermoso, Miguel es_ES
dc.contributor.authorHerrera Viedma, Enrique es_ES
dc.contributor.authorSeon Hong, Choonges_ES
dc.contributor.authorLee, Sungyonges_ES
dc.contributor.authorPomares Cintas, Héctor Emilio es_ES
dc.contributor.authorRojas Ruiz, Ignacio es_ES
dc.contributor.authorVillalonga Palliser, Claudia es_ES
dc.date.accessioned2017-02-23T09:51:53Z
dc.date.available2017-02-23T09:51:53Z
dc.date.issued2015
dc.identifier.citationBaños Legrán, O. et al. mDurance: A Novel Mobile Health System to Support Trunk Endurance Assessment. Sensors, 15: 13159-13183 (2015). [http://hdl.handle.net/10481/45009]es_ES
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10481/45009
dc.description.abstractLow back pain is the most prevalent musculoskeletal condition. This disorder constitutes one of the most common causes of disability worldwide, and as a result, it has a severe socioeconomic impact. Endurance tests are normally considered in low back pain rehabilitation practice to assess the muscle status. However, traditional procedures to evaluate these tests suffer from practical limitations, which potentially lead to inaccurate diagnoses. The use of digital technologies is considered here to facilitate the task of the expert and to increase the reliability and interpretability of the endurance tests. This work presents mDurance, a novel mobile health system aimed at supporting specialists in the functional assessment of trunk endurance by using wearable and mobile devices. The system employs a wearable inertial sensor to track the patient trunk posture, while portable electromyography sensors are used to seamlessly measure the electrical activity produced by the trunk muscles. The information registered by the sensors is processed and managed by a mobile application that facilitates the expert’s normal routine, while reducing the impact of human errors and expediting the analysis of the test results. In order to show the potential of the mDurance system, a case study has been conducted. The results of this study prove the reliability of mDurance and further demonstrate that practitioners are certainly interested in the regular use of a system of this nature.es_ES
dc.language.isospaes_ES
dc.publisherMDPIes_ES
dc.subjectMobile healthes_ES
dc.subjectDigital healthes_ES
dc.subjectPhysucal conditioninges_ES
dc.subjectPhysical therapy es_ES
dc.subjectRehabilitation es_ES
dc.subjectTrunk endurancees_ES
dc.subjectWearable inertial sensores_ES
dc.subjectWearable electromyography sensores_ES
dc.subjectMobile deviceses_ES
dc.titlemDurance: A Novel Mobile Health System to Support Trunk Endurance Assessmenten_EN
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

[PDF]

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem