Title: Evaluación de la eficacia del uso de un dispositivo neumático para prevenir alteraciones venosas en los viajes aéreos
Authors: Fernández Quesada, Fidel
Direction: Ros Díe, Eduardo
Martínez Marín, Manuel
Collaborator: Universidad de Granada. Departamento de Cirugía y sus Especialidades
Issue Date: 2016
Submitted Date: 18-Dec-2015
Abstract: La O.M.S reconoce la patología venosa asociada a los viajes como un riesgo global para la salud, que puede cursar desde unas molestias leves (edema y parestesias), a graves (trombosis venosa profunda y embolia pulmonar) que incluso podrían llegar a ser fatales. Como causa se suele destacar la inmovilidad prolongada, compresión venosa durante la posición sedente y las alteraciones de la coagulación en relación con las condiciones de presurización de la cabina (hipoxia-hipobárica y baja humedad relativa). La profilaxis se basa en medidas físicas, movilización y contención elástica; reservando las farmacológicas para pacientes de alto riesgo. OBJETIVO: valorar la eficacia de un dispositivo activador del retorno venoso (uso combinado de la bomba veno-muscular y del masaje de la esponja plantar) para activar el drenaje venoso. MÉTODO: estudio experimental no farmacológico (ensayo clínico aleatorizado con grupos cruzados), en condiciones de simulación controlada de las circunstancias de los viajes de avión bajo hipoxia-hipobárica e inmovilización. A 57 individuos se les ha sometido alternativamente a situación de vuelo simulado con y sin tratamiento de ejercicio incentivado, evaluando el comportamiento del sistema venoso de los miembros inferiores mediante diámetros externos y ecográficos, peso, pletismografía de oclusión venosa, cuestionarios de sintomatología y de calidad de vida, en todos ellos se realizó estudio basal, tras el procedimiento y a las dos semanas de la exposición. RESULTADOS: cuando se realizaba ejercicio incentivado se encontró reducción del edema medido por ecografía a nivel maleolar y franca mejoría en los parámetros pletismográficos de retorno venoso, aunque no apareció diferencia en la sintomatología referida tras la exposición a las condiciones de vuelo simulado en los sujetos que hacían ejercicio respecto a los que no. Estos efectos son reversibles pasadas dos semanas. CONCLUSIÓN: el ejercicio mediado por dispositivo neumático previene de forma eficaz las alteraciones venosas inducidas por la exposición a las condiciones experimentales.
WHO recognizes the venous pathology associated with travel as a global health risk, which can take from mild discomfort (edema and paresthesia), to severe (deep vein thrombosis and pulmonary embolism) that may even be fatal. It is often highlighted as a cause prolonged immobility, venous compression during sitting and coagulation disorders in relation to the conditions of cabin pressurization (hypoxic-hypobaric and low relative humidity). Prophylaxis is based on physical measures, mobilization and elastic containment; reserving the drug for patients at high risk. OBJECTIVE: To evaluate the efficacy of an activating device venous return (combined use of veno-muscular pump and massage sponge plant) to activate the venous drainage. METHOD: no drug experimental study (randomized clinical trial with crossover), under controlled circumstances simulation of air travel low-hypobaric hypoxia and immobilization. 57 individuals has been alternately subject them to flight situation simulated with and without encouraged exercise treatment, assessing the behavior of the venous system of the lower limbs by external diameters and ultrasound, weight, venous occlusion plethysmography, questionnaires of symptoms and Quality of Life, study was conducted in baseline and immediately following the procedure and within two weeks of exposure. RESULTS: when encouraged exercise was carried, edema reduction measured by ultrasound at ankle level and marked improvement in the plethysmographic parameters of venous return was found. Neverthless it did not show significance in the referred symptomatology following exposure to simulated flight conditions in subjects that develop exercising concerning those who do not. These effects are reversible after two weeks. CONCLUSION: Exercise mediated by pneumatic device effectively prevents venous alterations induced by exposure to the experimental conditions.
Sponsorship: Tesis Univ. Granada. Departamento de Cirugía y sus Especialidades
Publisher: Universidad de Granada
Keywords: Edema
Enfermedad tromboembólica venosa
Ensayos clínicos
Viajes aéreos
Trombosis
Alteraciones venosas
UDC: 616.14
317
3213
URI: http://hdl.handle.net/10481/41972
ISBN: 9788491254430
Rights : Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Citation: Fernández Quesada, F. Evaluación de la eficacia del uso de un dispositivo neumático para prevenir alteraciones venosas en los viajes aéreos. Granada: Universidad de Granada, 2016. [http://hdl.handle.net/10481/41972]
Appears in Collections:Tesis

Files in This Item:

File SizeFormat
25634380.pdf10.26 MBAdobe PDFView/Open
Recommend this item

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! OpenAire compliant DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback

© Universidad de Granada